FingerTec i-Kiosk 100 Plus Installation Guide User Manual

Installation guide, Step 2 mounting of terminals on a wall, I-kiosk 100 plus

Advertising
background image

Back Plate

4 feet / 1.2 meter

(recommended)

TCP/IP PORT (LAN)

USB PORT

RS232/RS485 SERIAL

CABLE PORT

USB Port

POWER ADAPTER PORT (A)

Step 1

Determine the Location and Positioning

of the Installation

Avoid installing the terminals in locations that has contact with

a strong light source (e.g direct sunlight, spotlight, fluorescent

light, etc)

Avoid installing the terminals in locations with high moisture or

condensation levels in the air

The recommended installation height of the terminal from the

ground is 1.2 meter.

Step 2

Mounting of Terminals on a Wall

After determining the height of the terminal from the ground

level and have made the relevant marks on the wall, drill the

screws into the wall to hang the back plate.

Refer to Appendix II for dimensions and measurements of instal-

lation.

Installation Guide

We Make Things Easy

w w w . f i n g e r t e c . c o m

i-Kiosk 100 Plus

Fingerprint Color Multimedia for Time Attendance &

Door Access Control System

Step 3

Wiring for Power Supply

i-Kiosk 100 Plus comes with a special key to unlock ports to power

and door access as shown in the diagram marked B. There are two

ways to connect the power to i-Kiosk 100 Plus.

1. Use the power adapter provided in the package and in-

sert the power adapter to the port marked A in the diagram.

2. Use power cables (black and red) to connect to a linear

power supply with specifications of 12VDC 3A. (Marked B)

POWER CABLE PORT (B)

Advertising