GTCO CR 1212 - Users Guide User Manual

Page 20

Advertising
background image

CR 1212 20


NOTE: When using Increment Mode, it’s recommended to use a resolution setting of 50 lpi
or higher.

How Increment Mode Works

The last report issued becomes the center of an imaginary square. The square’s sides
measure twice the increment value. The stylus/cursor can move anywhere inside the
imaginary square without the tablet issuing a report. When the stylus/cursor touches the
square, the increment is met and the tablet transmits a report. This point becomes the
center of a new imaginary square. The process repeats.

The following illustration shows the imaginary square created around a report point. The
increment is five.

The following example shows the reports issued as the stylus/cursor travels across the
tablet. The increment is ten. We have assumed that the first point collected is the origin (0,
0).