The points issued are:

How to Use Increment Mode

Send the mode command and then the increment value. The increment value is in counts
(of resolution) and can be a decimal whole number from 0 to 90. (The default is zero.) Add
32 (decimal), a required offset, to the desired increment and then convert the sum into
your preferred number base. For example, if the desired increment value is 10 (decimal),

desired increment

+32

= increment value in
hexadecimal

= increment value
in ASCII

10

+32

+ 2A hexadecimal

= ASCII

To disable Increment Mode, set the increment to zero with the ASCII space character (SP).