Carrier AQUAZONE 50PTH User Manual

Page 22

Advertising
background image

22

LEG

E

ND

AL

A

lar

m Rela

y

Con

ta

c

ts

AST

A

T

A

quast

a

t

BM

Blo

w

e

r M

o

to

r

BMC

B

lo

w

er Mot

o

r Capacit

or

BR

B

lo

w

er Rela

y

CB

Cir

c

u

it Bre

a

k

e

r

CC

Comp

ressor Cont

acto

r

DTS

Dischar

ge T

e

mper

atu

re Swit

ch

EC

M

E

lectr

onically Comm

ut

at

ed Mot

o

r

FP1

S

ensor

,

W

a

te

r Coil F

re

e

z

e

Pr

ot

ectio

n

FP2

S

ensor

,

A

ir Coil F

reez

e Pro

tect

ion

HP

Hig

h-Pr

ess

u

re Switc

h

HPWS

Hig

h-Pr

essu

re W

a

ter

S

w

it

ch

HWG

Hot

W

a

ter

G

ener

at

or

JW

J

u

mper Wire

LO

C

L

o

ss of

Ch

arge Pr

essu

re Swit

ch

LW

T

L

e

a

v

ing

W

a

te

r

T

e

mper

at

ure

MV

Mo

tor

iz

e

d V

a

lv

e

MVE

S

Mo

tor

iz

e

d V

a

lv

e End

S

witch

NEC

Nat

ion

al Elect

rical Code

P1

Fie

ld Wir

in

g

T

e

rm

inal Bl

oc

k

RH

Rel

a

ti

v

e

Humid

ity

RV

S

Re

v

e

rsing V

a

lv

e

S

o

len

o

id

SP

T

S

pace T

e

mper

atu

re Sen

s

o

r

TRANS

T

ransf

or

mer

De

lu

xe

D

Fie

ld

Line

V

o

lt

age

Wir

ing

R

e

la

y Cont

act

s

- N.C

.

Fie

ld

Lo

w V

o

lt

ag

e Wi

ri

ng

R

e

la

y Cont

act

s

- N.O

.

P

rin

ted

Cir

c

u

it

T

race

Lo

w P

ressure

Switch

O

p

ti

ona

l Wi

ri

ng

H

igh P

ressure

Sw

it

ch

Re

la

y/

Cont

acto

r C

o

il

C

ircuit

Br

eak

er

Co

nden

sa

te Float

Swit

ch

Splice Cap

S

o

len

o

id Coil

T

e

mper

a

tur

e Switch

Th

er

mist

or

G

rou

nd

Wi

re

N

u

t

* Optiona

l

wir

ing

.

NO

TES:

1.

Compre

ssor

an

d b

lo

w

er

mot

o

r t

her

mally p

rot

ecte

d i

n

te

rnal

ly

.

2.

All wir

ing to

t

he unit

m

u

st comply with

NE

C

an

d

lo

cal co

des

.

3.

208-

240

60 Hz un

its a

re wire

d

f

o

r 208

v

oper

at

ion.

F

o

r 240

v

60 Hz

oper

at

ion

s

wit

ch

RED wir

e t

o

O

R

G wir

e

. 2

2402

40v 50

Hz uni

ts a

re

wired

fo

r 24

0v oper

at

ion.

F

o

r 220

v 5

0

Hz oper

at

ion s

w

it

ch O

R

G

wire t

o

RED

. T

ransf

o

rm

er is ener

gy

limiti

ng or ma

y ha

v

e

circuit

brea

k

e

r.

4.

FP1 t

her

m

ist

or p

ro

v

ides lo

w t

e

mper

at

ure p

rot

ectio

n

f

o

r w

a

te

r.

When using

a

n

ti

fre

e

z

e

solu

tio

n

s

, cu

t JW3

ju

mper

.

5.

Ref

e

r

to

th

er

most

at

inst

allat

ion

, a

pplicat

ion

and

ope

ra

ti

on

man

u

a

l

fo

r

co

ntr

o

l wir

ing

to

t

he u

n

it

. Wi

re f

rom

ECM t

o

Y

” CX

M when

a

mot

o

ri

z

ed v

a

lv

e

is

not

used.

The

rmosta

t wir

ing m

u

st be “Class 1

and v

o

lat

age

r

a

ti

ng equa

l

to

or g

reat

er th

an unit

su

pply v

o

lt

ag

e

.

6.

24v alar

m

sig

nal sho

w

n.

F

o

r dr

y alar

m

con

tact

, cut

JW1

j

u

mper

.

Dr

y c

o

nt

act will be a

v

ail

a

b

le

b

e

tw

een AL1

a

nd AL2.

7.

T

ransf

o

rm

er seconda

ry

g

round

via g

reen

wir

e w

ith y

e

llo

w

st

ri

p

e

fr

om “

C

” t

e

rm

inal

to

c

o

n

tro

l b

o

x

8.

Aqu

a

stat

is su

pplie

d wit

h unit

and

m

u

st be

w

ired in

se

ri

es wit

h th

e

hot

l

eg to

t

he pump

. Aqu

a

stat

is

ra

te

d f

o

r v

o

lta

ges up to 27

7v

.

9.

F

o

r

fi

eld

-inst

alled

t

w

o-p

o

siti

on hot

w

a

ter

r

ehea

t coils disconne

ct

wire fr

om

te

rm

inal W1 and conne

ct

to f

ield-

su

pplie

d

h

o

t w

a

te

r

va

lv

e.

Fi

g.

23 —

Wi

ri

ng of 5

0

PTH,PT

V,

PTD02

6

-072

w

it

h Del

u

xe

D and

WSHP

O

p

en

Mu

lt

ip

le

Pr

oto

c

ol

Co

ntr

o

ls

(Si

ngl

e-

Phas

e 208

-2

30 V)

a50-8570

Advertising