Fig. 3 — 50ptv dimensional data – Carrier AQUAZONE 50PTH User Manual

Page 6

Advertising
background image

6

K - Configuration - Right Return

/Top Discharge

(Top View)

K - Configuration - Right Return -

Air Coil Opening

(Right Side View)

J - Configuration - Left Return -

Air Coil Opening

(Left Side View)

Front View

Isometric View

J - Configuration - Left Return

/Top Discharge

(Top View)

ASP

CSP

Front

Back

Back

Front

C

T

U

S

R

Air Coil

U

R

S

Air Coil

C

T

CSP

Power Supply
3/4”
HV Knockout

1/2”
Knockout

Low Voltage
1/2”
LV Knockout

CAP

Condensate
3/4” FPT

G

F

E

H

D

1.00”

1.68”

2ʼ Service Access

CAP

CSP

ASP

ASP

BSP

Air Coil

2ʼ Service Access

Filter Bracket

Access Panels

Field-Installed
Discharge Flange
(shipped loose inside
blower section)

O

Q

Air Coil Side

P

N

N

P

B

A

O

M

Air Coil Side

Front

Front

1.18”

1.63”

J

K

L

NOTES:
1. Condensate connection is stainless steel

3

/

4

in. female pipe thread (FPT).

2. Unit shipped with top and bottom filter rack and is not suitable for duct connection without

additional support.

3. Discharge flange is field-installed.
4. Shaded areas are recommended service areas, not required.

AIRFLOW CONFIGURATION

50PTV

UNIT

OVERALL CABINET

(in.)

WATER CONNECTIONS (in.)

WATER

CONNEC-

TIONS (in.)

- UNITS

WITH HWR

ELECTRICAL

KNOCKOUTS (in.)

DISCHARGE CONNECTIONS (in.)

DUCT FLANGE INSTALLED

(

0.10 in.)

RETURN CONNECTION

USING AIR COIL OPENING

(in.)

A

Width

B

Depth

C

Height

1

2

3

4

5

Loop

Water

FPT
(in.)

HWG

FPT
(in.)

1

2

J

1

/

2

-in.

Cond

K

1

/

2

-in.

Cond

L

3

/

4

-in.

Cond

M

(LH
rtn)

N

O

Supply

Width

P

Supply

Depth

Q

(RH
rtn)

R

S

Return

Depth

T

Return

Height

U

D

In

E

Out

F

HWG

In

G

HWG

Out

H

Cond-

ensate

Loop

in D

Loop
out E

Low

Voltage

Ext

Pump

Power

Supply

026

22.4

25.6

48.5

2.1

10.0

13.9

16.9

7.8

3

/

4

1

/

2

2.1

10.0

3.6

6.1

8.6

7.2

5.8

14.0

14.0

4.9

2.2

21.1

27.2

1.0

038

25.4

30.6

50.5

3.4

10.8

15.6

18.9

7.8

3

/

4

1

/

2

5.96 13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

27.2

1.0

049

25.4

30.6

54.5

3.4

10.8

15.6

18.9

7.8

1

1

/

2

5.96 13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

31.2

1.0

064,

072

25.4

30.6

58.5

3.4

10.8

15.6

18.9

7.8

1

1

/

2

5.96 13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

35.2

1.0

CODE

RETURN

DISCHARGE

J

Left

Top

K

Right

Top

LEGEND

ASP

Alternate Service Panel

BSP

Blower Service Panel

CAP — Control Access Panel
CSP

Compressor Service Panel

FPT

Female Pipe Thread

HV

High Voltage

HWG — Hot Water Generator
HWR — Hot Water Reheat
LV

Low Voltage

Fig. 3 — 50PTV Dimensional Data