Carrier AQUAZONE 50PTH User Manual

Page 4

Advertising
background image

4

Y Configuration - Left Return/Back Discharge

W Configuration - Left Return/Right Discharge - Air Coil Opening

W Configuration - Left Return/Right Discharge - Air Coil Opening

P Configuration - Right Return/Back Discharge - Air Coil Opening

N Configuration - Right Return/Left Discharge - Air Coil Opening

N Configuration - Right Return/Left Discharge - Air Coil Opening

Left
View

Right
View

Size

Right
View

ASP

BSP

Q

P

O

R

Blower
Outlet

Air Coil

S

ide

C

A

Y

F

ront

X

Z

C

P

A

R

O

Q

BSP

Left
Discharge

Back
Discharge

Condensate
3/4” FPT

H

CSP

Front

2 Service Access

Right Return

2 Service Access

3.25”

G

F

E

D

CAP

J

K

L

A

Power Supply
3/4” Knockout

1/2”

Knockout

Low Voltage

1/2” Knockout

Front

CSP

ASP

Left Return

Right
Discharge

Back
Discharge

Condensate
3/4” FPT

H

2 Service
Access

2 Service Access

Air Coil

S

ide

Blower
Outlet

BSP

P

M

N

O

Blower
Outlet

S

U

V

C T

B

CSP

Front

Front

Air Coil

1.1”

C

Air Coil

ASP

S

B

T

Front

CSP

M

BSP

Blower
Outlet

O

P

N

3.25”

1.6”

, 072

NOTES:

1. Condensate connection is stainless steel

3

/

4

in. female pipe thread (FPT).

2. Unit shipped with top and bottom filter rack and is not suitable for duct connection without

additional support.

3. Discharge flange is factory-installed.
4. Hanger kit is factory-installed.
5. Shaded areas are recommended service areas, not required.
6. Discharge can be modified in field. Return cannot be modified.

AIRFLOW CONFIGURATION

50PTH

UNIT

OVERALL CABINET

(in.)

WATER CONNECTIONS (in.)

WATER

CONNEC-

TIONS (in.)

- UNITS

WITH HWR

ELECTRICAL

KNOCKOUTS (in.)

DISCHARGE CONNECTIONS (in.)

DUCT FLANGE INSTALLED

(

0.10 in.)

RETURN CONNECTION

USING AIR COIL

OPENING (in.)

A

Width

B

Depth

C

Height

1

2

3

4

5

Loop

Water

FPT
(in.)

HWG

FPT
(in.)

1

2

J

1

/

2

-in.

Cond

K

1

/

2

-in.

Cond

L

3

/

4

-in.

Cond

M

(LH
rtn)

N

O

Supply

Height

P

Supply

Width

Q

(RH
rtn)

R

S

Return

Width

T

Return

Height

U

V

D

In

E

Out

F

HWG

In

G

HWG

Out

H

Cond-

ensate

Loop

in D

Loop
out E

Low

Voltage

Ext

Pump

Power

Supply

026

22.4

62.2

19.3

2.1

10.0

13.9

16.9

3.5

3

/

4

1

/

2

2.1

10.0

3.6

6.1

8.6

3.6 2.0

12.5

15.5

3.6 2.0

33.8

16.2

2.3 1.5

038

25.4

71.2

21.3

3.4

10.8

14.6

18.9

3.4

3

/

4

1

/

2

5.96 13.13

3.4

6.1

8.6

3.1 1.2

19.0

17.5

3.1 1.0

34.8

18.2

3.1 1.5

049

25.4

76.2

21.3

3.4

10.8

15.6

18.9

3.4

1

1

/

2

5.96 13.13

3.6

6.1

8.6

3.1 1.2

19.0

17.5

3.1 1.0

39.8

18.2

3.1 1.5

064,072

25.4

81.2

21.3

3.4

10.8

15.6

18.9

3.4

1

1

/

2

5.96 13.13

3.6

6.1

8.6

3.1 1.2

19.0

17.5

3.1 1.0

44.8

18.2

3.1 1.5

CODE

RETURN

DISCHARGE

N

Right

Left

P

Right

Back

W

Left

Right

Y

Left

Back

LEGEND

ASP

Alternate Service Panel

BSP

Blower Service Panel

CAP — Control Access Panel
CSP

Compressor Service Panel

FPT

Female Pipe Thread

HWG — Hot Water Generator
HWR — Hot Water Reheat

Fig. 1 — 50PTH026-072 Dimensional Data