Mounting Height

Table

3. Uncrating/

Packaging

Check for shipping damage. If any damage is found, document the damage

with the shipping agency and immediately contact your Distributor. If you are

an authorized Distributor, follow the FOB freight policy procedures provided by

Thomas & Betts for this product.
Because of their modular design, these heaters are packaged in sections and

require field assembly. The burner/control box is in one carton, and the tubes

are packaged in one, two, or three cartons depending on the length of the sys-

tem. Each shipped-separate option has its own carton. Be sure all parts are at

the site before beginning installation.
Burner/Control Box Carton - For the convenience of both the stocking and

the non-stocking distributor, Model VR burner/control boxes have two differ-

ent packaging schemes.

Read carefully to determine whether or not the

burner/control box requires field conversion before being installed. Model

GVR burner/control box is available in specific sizes only.
(1) Burner/Control Box with Conversion Package - Model VR, 60 Hz only

Recommended Minimum Mounting Height

Reflector

Position

Models VR/GVR, Size (000 BTUH Input)

50

75

100

125

150

175

200

feet M feet M feet M feet M feet M feet M feet M

Horizontal 11 3.4 12 3.7 13 4.0 15 4.6 16 4.9 17 5.2 18 5.5

30° Angle

9 2.7 10 3.0 11 3.4 13 4.0 14 4.3 15 4.6 16 4.9

45° Angle

8 2.4 9 2.7 10 3.0 11 3.4 13 4.0 14 4.3 15 4.6

Package

Contents

VR 50

Factory-assembled Size 50,000 BTUH heater

VR 75/100

Factory-assembled Size 75,000 BTUH heater

Conversion kit to change to a Size 100,000 BTUH heater

VR 125/150

Factory-assembled Size 125,000 BTUH heater

Conversion kit to change to a Size 150,000 BTUH heater

VR175/200

Factory-assembled Size 175,000 BTUH heater

Conversion kit to change to a Size 200,000 BTUH heater

(2) Burner/Control Box Factory Built to a Specific Size (Models VR & GVR)

- If the burner/control box carton does not have a label about field conver-

sion, the carton contains a burner/control box factory-built to a specific size.

Check the rating plate to verify size and type of gas.

Tube Cartons (Models VR & GVR) - Tubes are also packaged so that a mini-

mum number of cartons will cover all lengths of heater systems. This package

identification system applies to all heaters, whether shipped from distributor

stock or shipped to order from the factory. Before beginning installation, verify

that the packages at the job site match the length of heater being installed.

Reflectors, wire reflector retainers, hanger bars, tube brackets, compression

couplings, and hardware bags with required reflector and tube hardware are

included in each carton.

should be located parallel to the wall. The distance from the wall is determined

by whether the reflectors will be angled or horizontal.
For spot heating applications, the tubular system should be located to direct

the rays toward the area requiring heat. Depending on the installation, this

can be done from directly overhead or reflector angled from the side. U-tube

configurations are often best suited for overhead spot heating applications.

Refer to the recommended minimum mounting heights below. Use the mount-

ing height, the size of the heater, the heater configuration, and the application

conditions to determine the most efficient location of the heater.