5tank installation – SeaLand DHT-L Series Holding Tank User Manual
Page 10
 
10
Dometic Holding Tanks
Components and Functions
•	 Pre-installed	inlet	and	two	outlets	for	dockside	and	seacock	connections
•	 Inlet	and	outlet	fittings	rotate	to	facilitate	hose	connection	from	virtually	any	direction	(fig.		3			D,	
page 3)
•	 Discharge	tubes	have	special	non-clogging	design
•	 Vacuum	relief	valve	protects	tank	from	over-pressure	collapse
•	 Extra	fittings	allow	tank	conversion	to	various	inlet	and	outlet	configurations 
–		one	inlet,	two	outlets	(fig.		3			A,	page	3) 
– one inlet, one outlet on same side of tank (fig . 3 B, page 3) 
– one inlet, one outlet on different sides of tank (fig . 3 C, page 3)
• Meets ISO 8099 requirements
4.1 Features
5
Tank Installation
Determine properly located surface that will support the entire area of the tank . If a mounting 
surface needs to be fabricated, use marine grade plywood at least 13 mm thick . If installing with 
restraining straps, include toe blocks on mounting surface (fig . 4 B, page 4) .
Integrated Mounting Feet Installation		(fig.		4			A,	page	4)
In the four mounting feet locations around bottom of tank, use at least 6 mm dia . (#12) fasteners 
with 19 mm maximum dia . (0 .75 in .) washers to fasten tank to surface .
Restraining Strap Installation (fig . 4 B, page 4)
With restraining straps of 31 mm (1 .25 in .) maximum width, fasten straps over top of tank to 
mounting surface on both sides of tank, positioning the straps within the channels on the tank .
5.1
Choose a location for the holding tank
5.2
Prepare a mounting surface
5.3
Install tank on mounting surface
Caution! 
The holding tank should not be exposed to temperatures above 45°C (120°F) . Do not place 
tank near heat sources such as engine manifolds, water heaters, generators, etc .
Caution! 
Do not install tank on projections, such as fastener heads, which could puncture the tank . 
Do not allow holding tank to block free flow of bilge water .
A	holding	tank	should	be	positioned	as	low	in	the	hull	as	possible.	Most	connecting	hoses	and	pipes	
should slope downward toward the tank to permit gravity drainage and prevent possible hose odor 
permeation . Hose connected to an overboard discharge pump should drain away from the tank .
In addition to dimensions of tank (fig . 1 , page 2), allow 16 cm (about 6 inches) above tank to 
easily make plumbing connections .
SERVICE	ACCESS	–	Because	Dometic	holding	tanks	may	require	minimal	service	in	normal	 
operation, the tank must be installed so that there is easy access to the inspection port .
3
3
1
4
4
4
3
3