Hose Installation
Dometic Holding Tanks
• Vent fitting on Dometic holding tank will accom-
modate 16 mm ID vent hose .
• Install a Dometic vent filter in the vent line to
absorb malodorous gases, letting only freshened 
air out of the vent .
Item
Description
1
Vent hose
2
Vent filter
3
Holding tank
Note 
Vent	line	must	not	have	any	low	runs	that	
can create a liquid trap .
Vent Hose (fig. 9 , page 5)
9
Do	not	restrict	the	ability	to	pull	the	hose	or	pipe	(fig.		10		A,	page	6).
Avoid	binding	corners	and	sharp	bends	(	fig.		10		B,	page	6).
Do not use wire ties to secure hose or pipe . Support flexible hose every 0 .3 m (12 inches) and 
support rigid pipe every 1 .5 m (5 feet) .
Where possible use a support trough under the hose or pipe (fig . 10 C, page 6) .
Bulkhead Penetrations (fig. 11 , page 6)
Check each side of a bulkhead to ensure that there will be no cutting into:
•	 fuel	or	water	tanks
•	 wiring	or	pipes
•	 reinforcement	stringers	(4)	that	support	the	hull
When creating new holes, avoid tabs (1) and stringers (4) that hold bulkheads or partitions in place . 
Provide additional reinforcement so that structural integrity is not compromised .
•	 avoid	(2)
•	 possible	(3)
Hose and Heat Sources
The operating temperature of flexible hose prohibits exposure to sources of high or direct heat, such 
as light bulbs or engine manifolds . If any part of the hose system must be run close to a heat source, 
use rigid pipe instead of hose .
When connecting flexible hose to plastic fittings (fig . 12 , page 7), use special hose lubricant which is 
supplied	with	the	Dometic	holding	tank.	Apply	lubricant	around	end	of	fitting	and	inside	end	of	hose	
that connects to fitting . The Dometic lubricant makes connections easier . Do not use any other 
lubricant, sealant or adhesive .
Hose Clamps (fig. 13 , page 7)
Each hose connection should be secured with two hose clamps to prevent possibility of leaks .
Position the clamp screws 180° apart from each other and tighten the clamp . Do not over-tighten 
clamps or they may cut into the hose . If over-tightening is the only way to stop a leak, the hose- 
to-fitting connection is not sized correctly, and an adapter or different size fitting is required .
6.3
Recommended hose installation methods
6.4
Connecting hose to plastic fittings
10
12
10
10
11