Connections, Removable terminal plug connection – Toa VM-3000 Series User Manual

Page 108

Advertising
background image

108

Recommended ferrule terminals for power supply cables
(made by Phoenix Contact)

Crimping tool: CRIMPFOX UD6-4 (made by Phoenix Contact)

Wiring procedures

Procedures below are for the removable terminal plug with fixing screws.

Step 1. Loosen the terminal screw and insert the

cable lead.

Step 2. Tighten the screw.

Pull on the cable lead to ensure it is securely
connected.
If the lead pulls out, loosen the screw and
follow the above procedures again.

Step 3. Insert the terminal plug into the corresponding

terminal block in the unit's rear panel.

Note
Do not reverse Steps 1 – 2 and 3 above.
Force is applied to the connected receptacle pins
while tightening the terminal screw and they may be
damaged, resulting in bad connector contact.

Solid cable and stranded cable

Shielded cable

7 mm*

7 mm*

15 mm

1

1

2

3

To tighten

To loosen

Removable terminal plug
(accessory)

Terminal screw

Screwdriver

Cable sheath to trim

Insulation sleeve

Contact section

Insulation sleeve

Contact section

a

l

2

a

1

a

2

l

1

l

2

l

1

b

b

Model Number

a

l

1

l

2

AI 0,34-8 TQ

AI 0,5-8 WH

2 mm

2.5 mm

12.5 mm

14 mm

8 mm

8 mm

b

0.8 mm

1.1 mm

Model Number

a

1

l

1

l

2

AI 1,5-8 BK

AI-TWIN 2 x 1,5-8 BK

6.6 mm

a

2

3.6 mm

14 mm

16 mm

2.3 mm

8 mm

8 mm

a

3.4 mm

b

1.8 mm

* Expose 8 mm or more when using the

above ferrule terminal, and cut off an extra
conductor protruding from the sleeve.

14. CONNECTIONS

14.1. Removable Terminal Plug Connection

Notes
• Do not use a micro screwdriver. Sufficient torque is not given to the screws when tightening them, and

connections may not be secured.

• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened

and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

• When connecting 2 cables or a shielded cable to a single terminal,

use a ferrule terminal with an insulation sleeve to crimp the cables
because such cable conductors could become loose.

Recommended ferrule terminals for signal cables
(made by Phoenix Contact)

Advertising