Microphone announcement

Make emergency broadcasts by holding down the
emergency microphone’s Talk key.

Press either the All-Zone Call key or Output key to select the output zone.

(If the zone is not selected, emergency broadcasts are made over all zones.)

To terminate the emergency broadcast, reset the emergency mode using one of the following methods:

Press the Reset key on the front panel of the VM-3360VA or VM-3240VA.

Press the RM-300MF Fireman’s Microphone’s Emergency Reset key.

Input a reset signal to the Emergency Control Input terminals on the rear panel of the VM-3240VA, VM-3360VA, VM-
3240E, or VM-3360E which has been assigned a reset function.

Press the Emergency Activation switch.

Normal status

Automatic emergency announcement

Press the Alert or Evacuation Announcement Start key
to broadcast the Alert or Evacuation announcement.

6.4.2. Fireman’s microphone emergency broadcasts

Microphone announcement

Make emergency broadcasts by holding down the RM-
300MF’s emergency microphone’s Talk key.

Press the RM-320F Fireman’s Microphone Extension’s Zone Selector key to select the output zone.

(If the zone is not selected, broadcasts are made over all zones.)

To terminate the emergency broadcast, reset the emergency mode using one of the following methods:

Press the Reset key on the front panel of the VM-3360VA or VM-3240VA.

Press the RM-300MF Fireman’s Microphone’s Emergency Reset key.

Input a reset signal to the Emergency Control Input terminal on the rear panel of the VM-3240VA, VM-3360VA, VM-
3240E, or VM-3360E which has been assigned a reset function.

Press theRM-300MF’s Emergency Activation switch.

Normal status

Automatic emergency announcement

Press the RM-300MF’s Alert or Evacuation
Announcement Start key to broadcast the Alert or
Evacuation announcement.

6.4.3. Making automatic emergency announcements using the control signal input

Alert or Evacuation announcements are broadcast over the zones assigned to the Emergency Control Input terminal.

Automatic fire alarm system is activated and an emergency control signal is input to the Emergency Control Input terminal.

To terminate the emergency broadcast, reset the emergency mode using one of the following methods:

Press the Reset key on the front panel of the VM-3360VA or VM-3240VA.

Press the RM-300MF Fireman’s Microphone’s Emergency Reset key.

Input a reset signal to the Emergency Control Input terminal on the rear panel of the VM-3240VA, VM-3360VA, VM-
3240E, or VM-3360E which has been assigned a reset function.

Normal status

6.4. Summary of Emergency Broadcast Procedures

6.4.1. Making emergency broadcasts from the VM-3240VA or VM-3360VA

Advertising