Connections between vm amplifiers – Toa VM-3000 Series User Manual

Page 131

Advertising
background image

131

Cat. 5 STP

VM-3240VA/3360VA

VM-3240E/3360E

Unit ID No. 1

VM-3240E/3360E

Cat. 5 STP

RJ45 male connector

3 4 5 6

ON

Unit ID No. 2

3 4 5 6

ON

3 4 5 6

ON

ID No. 1

ID No.

DIP switch

SW 3

(+1)

SW 4

(+2)

SW 5

(+4)

SW 6

(+8)

ON

OFF

OFF

OFF

3 4 5 6

ON

ID No. 2

OFF

ON

OFF

OFF

3 4 5 6

ON

ID No. 3

ON

ON

OFF

OFF

3 4 5 6

ON

ID No. 4

OFF

OFF

ON

OFF

3 4 5 6

ON

ID No. 5

ON

OFF

ON

OFF

3 4 5 6

ON

ID No. 6

ID No.

DIP switch

SW 3

(+1)

Note
SW 3 – 6 are DIP switch numbers.

SW 4

(+2)

SW 5

(+4)

SW 6

(+8)

OFF

ON

ON

OFF

3 4 5 6

ON

ID No. 7

ON

ON

ON

OFF

3 4 5 6

ON

ID No. 8

OFF

OFF

OFF

ON

3 4 5 6

ON

ID No. 9

ON

OFF

OFF

ON

14.10. Connections between VM Amplifiers

Notes

When connecting 2 VM-3240E/3360E units or more in a system, set the Unit ID with the DIP switch located
on each unit’s rear panel. Make individual Unit ID numbers different because duplicating ID numbers causes
unit malfunction.

When the Unit ID of VM-3240E/3360E has been changed while the system power is on, be sure to restart
the system by pushing the front-mounted reset switch on the VM-3240VA/3360VA.