Vm-3000 cable usage table – Toa VM-3000 Series User Manual
Page 136
136
Terminal
Name
Equipment
Receptacle
Plug
Cable Type
Plug
Equipment
Receptacle
Terminal
Name
Equipment
Terminal to Connect
Cable Type
Equipment to be Connected to
[VM-3240VA/3360VA]
AC IN
3P inlet
AC plug
Supplied cable
AC plug
AC OUTLET AC 230 V, 50/60 Hz
POWER IN
24 V
Screw terminal
Round terminal
10 – 8 AWG
Round terminal
Screw terminal
DC POWER
OUT
VX-2000DS
PS OUT
Screw terminal
Round terminal
10 – 8 AWG
Round terminal
Screw terminal
PS IN
VX-2000DS
CTRL OUT
Screw terminal
block
Unprocessed
cable end
28 – 22 AWG
–
–
–
Other control unit
CTRL IN
Screw terminal
block
Unprocessed
cable end
28 – 22 AWG
–
–
–
Other control unit
EXT. PA
LINK
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
PA LINK
(VP-200VX)
VP-2241/2421
VM LINK
OUT
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
VM LINK IN
VM-3240E
/3360E
EMERGENCY
CONTROL IN
RJ45 (female)
RJ45 (male)
Cat. 5 STP
–
–
–
Fire alarm
system/Other
control unit
DS LINK
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
DS SF LINK
VX-2000DS
STATUS
OUT
RJ45 (female)
RJ45 (male)
Cat. 5 STP
–
–
–
Other unit
LAN
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
–
HUB
RM LINK IN
RJ45 (female)
RJ45 (male)
Cat. 5 STP
Unprocessed
cable end
Screw terminal
DC IN/DATA
/AUDIO
OUT/
SHIELD
RM-300MF (Wall
mount bracket
unit)
RJ45 (male)
RJ45 (female)
LINK
RM-200M
Terminal
Name
Equipment
Receptacle
Plug
Cable Type
Plug
Equipment
Receptacle
Terminal
Name
Equipment
Terminal to Connect
Cable Type
Equipment to be Connected to
[VM-3240E/3360E]
AC IN
3P inlet
AC plug
Supplied cable
AC plug
AC OUTLET AC 230 V, 50/60 Hz
POWER IN
24 V
Screw terminal
Round terminal
10 – 8 AWG
Round terminal
Screw terminal
DC POWER
OUT
VX-2000DS
PS OUT
Screw terminal
Round terminal
10 – 8 AWG
Round terminal
Screw terminal
PS IN
VX-2000DS
CTRL OUT
Screw terminal
block
Unprocessed
cable end
28 – 22 AWG
–
–
–
Other control unit
CTRL IN
Screw terminal
block
Unprocessed
cable end
28 – 22 AWG
–
–
–
Other control unit
EXT. PA
LINK
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
PA LINK
(VP-200VX)
VP-2241/2421
VM LINK
OUT
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
VM LINK IN
VM-3240E
/3360E
EMERGENCY
CONTROL IN
RJ45 (female)
RJ45 (male)
Cat. 5 STP
–
–
–
Fire alarm
system/Other
control unit
DS LINK
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
DS SF LINK
VX-2000DS
STATUS
OUT
RJ45 (female)
RJ45 (male)
Cat. 5 STP
–
–
–
Other unit
VM LINK
IN
RJ45 (female)
RJ45 (male)
Cat. 5 STP
RJ45 (male)
RJ45 (female)
VM LINK
OUT
VM-3240VA
/3360VA/3240E
3360E
15. VM-3000 CABLE USAGE TABLE
This table shows the cables to be used in the VM-3000 and their connection locations.