DGC-500 Functional Description

3-1

Figure 3-1. DGC-500 Function Block Diagram

SECTION 3 • FUNCTIONAL DESCRIPTION

INTRODUCTION

This section describes how the DGC-500 functions and explains its operating features. A detailed description
of each function block is provided in the paragraphs under the heading of DGC-500 Function Blocks.

DGC-500 operating features are described under the heading of Software Operation.

DGC-500 FUNCTION BLOCKS

To ease understanding, DGC-500 functions are illustrated in the block diagram of Figure 3-1. The following
paragraphs describe each function in detail.

Power Supply

The internal, switch-mode power supply uses the applied battery voltage to generate operating power for the
internal circuitry of the DGC-500. The power supply accepts a nominal battery voltage of 12 or 24 Vdc and
has an operating range of 8 to 32 Vdc. Battery voltage is applied to terminals P20 (+) and P21 (–).

Battery Voltage Sensing

Voltage applied to the power supply is filtered and reduced to a suitable level for sensing by the
microprocessor.

Microprocessor

The microprocessor controls the overall functionality of the DGC-500 and makes decisions based on
programming and system inputs.