Winco DGC-500 User Manual

Page 89

Advertising
background image

DGC-500 Installation

5-15

20. Press the Raise/Scroll pushbutton. The screen at right is displayed.

Connect a resistance of 125 ohms across the oil pressure sender input (P13
and P19). Press the Lower/Scroll pushbutton.

21. Press the Raise/Scroll pushbutton. The screen at right is displayed.

Connect a resistance of 150 ohms across the oil pressure sender input (P13
and P19). Press the Lower/Scroll pushbutton.

22. Press the Raise/Scroll pushbutton. The screen at right is displayed.

Connect a resistance of 175 ohms across the oil pressure sender input (P13
and P19). Press the Lower/Scroll pushbutton.

23. Press the Raise/Scroll pushbutton. The screen at right is displayed.

Connect a resistance of 200 ohms across the oil pressure sender input (P13
and P19). Press the Lower/Scroll pushbutton.

24. Press the Raise/Scroll pushbutton. The screen at right is displayed.

Connect a resistance of 225 ohms across the oil pressure sender input (P13
and P19). Press the Lower/Scroll pushbutton.

After step 24 is completed successfully and the Raise/Scroll pushbutton is pressed, the INPUT CALIBRATE
FUNCTION screen appears and signals that calibration is complete.

Advertising