Audio Talk Device Settings

Audio Talk Device settings are used to configure Remote Audio Talk Devices for use on the VIGIL Server.  These can be
IP Cameras or IP Audio Devices.

Name

Enter a name for the Audio Talk Device. This can be
used to describe the location of the Audio Talk
Device.

Type

Select the type of Audio Talk Device.  This can be an
Audio Talk capable IP Camera or IP Audio Device.

Address

The IP address of the Audio Talk Device.

Data Port

The Data Port used on the Audio Talk Device.

RTSP Port

The RTSP Port used on the Audio Talk Device.

User Name / Pass-

word

The user name and password for the Audio Talk
Device.

Live Audio Settings

Force to User Soft-

ware Live

When enabled, live audio will be routed through the VIGIL Server’s audio output instead of the capture
card’s audio output.   This function is only available with some capture cards.

Audio Storage Drives

Create and configure Audio Storage Drives.

Audio Storage Drives are defined in the same way as Video Storage Drives. It is recommended that the Audio Storage
Drive
be on a different drive than the Video Storage Drive(s).

Audio Talk / Chat

Audio Device

Select the audio device that will be used by the VIGIL Server for voice communication in Audio Talk Mode.
Set to ‘none’ to disable Audio Chat.