11 d/a reference voltage setting – ADLINK ACL-8112 Series User Manual

Page 27

Advertising
background image

Installation

• 19

2.11 D/A Reference Voltage Setting

The D/A converter's reference voltage source can be internally or externally
generated. The external reference voltage is connected via CN3 pin
31(ExtRef1) and pin 12(ExtRef2), see section 3.1. The D/A reference source
of channel 1 and channel 2 are selected using JP2 for the ACL-8112DG/HG
and JP6 and JP7 for the ACL-8112PG respectively. Possible settings are
shown below:

Figure 2.8 D/A Voltage Setting

D/A CH1 is External

D/A CH2 is External

JP2 or JP7 JP6

INTREF

ExtRef2

ExtRef1

INTREF

D/A CH1 is External

D/A CH2 is Internal

D/A CH1 is Internal

D/A CH2 is External

D/A CH1 is Internal

D/A CH2 is Internal

JP2 or JP7 JP6

INTREF

ExtRef2

ExtRef1

INTREF

JP2 or JP7 JP6

INTREF

ExtRef2

ExtRef1

INTREF

JP2 or JP7 JP6

INTREF

ExtRef2

ExtRef1

INTREF

Advertising