7.10 _8112_AD_Set_Mode

Description

This function is used to set the A/D trigger and data transfer mode by
means of writing data to the mode control register. The hardware initial
state for the ACL-8112 is set as AD_MODE_1 software( internal) trigger
with program polling data mode.

A/D Mode

Description

AD_MODE_0

External Trigger, Software Polling

AD_MODE_1

Software Trigger, Software Polling

AD_MODE_2

Timer Trigger, DMA Transfer

AD_MODE_3

External Trigger, DMA Transfer

AD_MODE_4

External Trigger, Interrupt Transfer

AD_MODE_5

Software Trigger, Interrupt Transfer

AD_MODE_6

Timer Trigger, Interrupt Transfer

AD_MODE_7

Not Used

Note: All analog input modes selection should match with the hardware

settings, which is described in the hardware users manual.

Syntax

int _8112_AD_Set_Mode(int ad_mode )
int _8112pg_AD_Set_Mode(int ad_mode )

Argument:

ad_mode:

AD trigger and data transfer mode

( please refer above table.)

Return Code:

ERR_NoError
ERR_BoardNoInit
ERR_InvalidMode