• 65

For the ACL-8112DG card, the gain values supported are 1, 2, 4, and 8.
The relationship between analog input voltage range, gain and input
type are specified in the table below.

** this table only applies for the ACL-8112DG ( low gain) card.

AD_INPUT

GAIN

Input type

(Bipolar or

Unipolar)

Input Range

AD_B_5_V

1

Bipolar

±5V

AD_B_2_5_V

2

Bipolar

±2.5V

AD_B_1_25_V

4

Bipolar

±1.25V

AD_B_0_625_V

8

Bipolar

±0.625V

AD_U_10_V

1

Unipolar

0V ~ 10V

AD_U_5_V

2

Unipolar

0V ~ 5V

AD_U_2_5_V

4

Unipolar

0V ~ 2.5V

AD_U_1_25_V

8

Unipolar

0V ~ 1.25V

For the ACL-8112PG card, the gain values supported are 1,2,4,8,and
16.

The initial value of the gain is '1'. The relationship between gain and
input voltage ranges is specified by following tables:

when input voltage range is set to

±

5 V (JP9),

Gain Code

Gain

Input Range (V)

AD_GAIN_1

X 1

±

5 V

AD_GAIN_2

X 2

±

2.5 V

AD_GAIN_4

X 4

±

1.25 V

AD_GAIN_8

X 8

±

0.625 V

AD_GAIN_16

X 16

±

0.3125V

when input voltage range is set to

±

10 V(JP9),

Gain Code

Gain

Input Range (V)

AD_GAIN_1

X 1

±

10 V

AD_GAIN_2

X 2

±

5 V

AD_GAIN_4

X 4

±

2.5 V

AD_GAIN_8

X 8

±

1.25 V

AD_GAIN_16

X 16

±

0.625 V

Advertising