9 d/a output register – ADLINK ACL-8112 Series User Manual
Page 48

40
• Registers
4.9
D/A Output Register
The D/A converter will convert the D/A output register data to an analog
signal. The register data at address Base + 4 and Base + 5 are used for D/A
channel 1and Base +6 and Base +7 for D/A channel 2.
Address : BASE + 4 & BASE + 5
Attribute: write only
Data Format: (for D/A Channel 1)
Bit
7
6
5
4
3
2
1
0
Base + 4
DA7
DA6
DA5
DA4
DA3
DA2
DA1
DA0
Base + 5
X
X
X
X
DA11 DA10 DA9
DA8
Address : BASE + 6 & BASE + 7
Attribute: write only
Data Format: (for D/A Channel 2)
Bit
7
6
5
4
3
2
1
0
Base + 6
DA7
DA6
DA5
DA4
DA3
DA2
DA1
DA0
Base + 7
X
X
X
X
DA11 DA10 DA9
DA8
DA0 is the LSB and DA11 is the MSB of the 12 bits data.
X: don't care
Note: The D/A registers are "double buffered" so that the D/A analog output
signals will not updated until the second (high) byte contains data or
written to. This will ensure a single step transition for a D/A conversion.