ADLINK ACL-8112 Series User Manual
Page 44
36
• Registers
( This table is only for the ACL-8112DG: Low Gain Card)
G3
G2
G1
G0
GAIN
Bipolar
or
Unipolar
Input Range
1
0
0
0
0.5
Bipolar
±
10V
0
0
0
0
1
Bipolar
±
5V
0
0
0
1
2
Bipolar
±
2.5V
0
0
1
0
4
Bipolar
±
1.25V
0
0
1
1
8
Bipolar
±
0.625V
0
1
0
0
1
Unipolar
0V ~ 10V
0
1
0
1
2
Unipolar
0V ~ 5V
0
1
1
0
4
Unipolar
0V ~ 2.5V
0
1
1
1
8
Unipolar
0V ~ 1.25V
Table 4.2-2 Function of the Gain Control Bits
For the ACL-8112PG, the maximum range is changed by hardware jumper
configuration. JP9 is used to change the maximum analog input range form
±
5V or
±
10V. If JP9 is set as
±
5V, the analog input range is listed as below.
G3
G2
G1 G0
GAIN
Analog Input Range
0
0
0
0
1
±
5V
0
0
0
1
2
±
2.5V
0
0
1
0
4
±
1.25V
0
0
1
1
8
±
0.625V
0
1
0
0
16
±
0.3125V
Table 4.2-3 Analog Input Range ( max. is
±5V)
If JP9 is set as
±
10V, the analog input range is listed as below
G3
G2
G1 G0
GAIN
Analog Input Range
0
0
0
0
1
±
10V
0
0
0
1
2
±
5V
0
0
1
0
4
±
2.5V
0
0
1
1
8
±
1.25V
0
1
0
0
16
±
0.625V
Table 4.2-4 Analog Input Range (max. is
±10V)