7 Appliance installation

7.1

Scope of delivery

The appliance is delivered in a single carton with a document

pack and fittings.

i

IMPORTANT:

The flues package will be ordered according to the

configuration of the installation.

• Please check the contents.

1

4.7

2

2.1

2.2

2.3

2.5

2.4

3

4

4.1

4.2

4.3

4.4

4.5

4.6

Key

1

boiler

(x1)

2

Accessories bag

(x1)

2.1

Connection bag

(x1)

- Heating return valve

(x1)

- Cold water inlet valve

(x1)

- Heating flow valve

(x1)

- Domestic hot water connection

(x1)

- Gas isolation valve

(x1)

2.2

Hanging bracket

(x1)

2.3

Screws and wall plugs bag

(x1)

2.4

Seals bag

(x1)

- flat seal ½"

(x2)

- flat seal ¾"

(x5)

- Flat seal for cold water inlet ¾"

(x4)

2.5

PRV pipe

(x1)

3

Wall template

(x1)

4

Documents bag

(x1)

4.1

Installation and servicing manual

(x1)

4.2

flue book

(x1)

4.3

Instructions for use

(x1)

4.4

Extended guarantee leaflet

(x1)

4.5

Guarantee envelope pack

(x1)

4.6

Magnetic lighting instruction label

(x1)

4.7

Gas conversion label

(x1)

7.2

Recommendations before installing

7.2.1

Domestic hot water circuit design

Water pressure

The minimum working pressure to obtain the maximum domestic

flow is 1,0 bar.

The maximum working pressure of the domestic hot water circuit

is 10 bar. If the cold water supply pressure exceeds this, then a

pressure-reducing valve must be fitted in the supply to the boiler.

‘Hard’ water areas

The temperatures within the heat exchanger are limited by the

boiler control system to minimise scale formation within the hot

water pipework. However, in areas where the water is ‘hard’ (i.e.

more than 200 mg/L of calcium carbonate), it is recommended

that the hot water setting is reduced and that a scale reducer is

fitted, refer to the manufacturer’s instructions or consult the local

water company for additional advice.

Domestic water flow rate

The domestic hot water flow has a restrictor, factory fitted, which

reduces the flow to a maximum of:

- 24 : 8/min,

- 28 : 10/min,

Central Heating water flow rate

If it is necessary to alter the flow rate, the system can be fitted

with a lockable balancing valve in the main flow or return pipes.

- Heating circuit design

5

4

3

2

1

6

7

8

Key

1 Drain point

2 External bypass (if required)

3 Domestic hot water out

4 Domestic cold water supply in

5 boiler

6 Additional expansion vessel (if required)

7 Heating return circuit

8 Heating flow circuit

9 Optional balancing valve

INSTALLATION

- 9 -