0020140413_01 - 09/12 - Glow-worm

18.7.2

2A fuse Rating

• For access, refer to chapter "Main PCB".

• The fuse is located at top right hand side of the PCB, see

chapter "Electrical connection >Wiring diagram".

18.7.3

User interface PCb

A

C

B

B

5

4

3

2

1

Key

1 User interface

2 Retaining slots

3 User interface PCb

4 Retainings clips

5 Control Panel

• Remove the user interface (1) easing back the two retaining

slots (2).

• Ease back the two PCB retaining clips (4) and withdraw the

PCB from the retaining lugs.

• Remove the electrical connections to the PCB.

• When refitting the user interface, ensure the leads are not

trapped.

18.7.4

Mains supply cable

e

DANGER:

The main supply cable must be replaced by a qualified

and competent electrician.

• If the main supply cable is damaged, replace it refering to the

chapter "Electrical connection".

19 Spare parts

In order to guarantee the safe and prolonged life of the product,

manufacturers genuine spare parts must be used.

i

IMPORTANT:

This appliance displays a CE Mark of conformity. Only

use the manufacturer’s genuine, new spare parts.

• Ensure that spare parts are correctly mounted in the right

position and direction. After fitting any spare part or servicing,

the appliance must be tested for its safe operation.