Maintenance, 4 hydraulic block – Glow-worm Easicom User Manual

Page 42

Advertising
background image

0020140413_01 - 09/12 - Glow-worm

18.4 Hydraulic block

11

16

9

10

8

7
6

24

17

13

12

5

4

2

1

18

19

21

22

14

15

20

23

3

25

27

26

30

30

28

29

Key

1 Three-way valve

2 Three-way valve electrical plug

3 Three-way valve electrical plug retaining clip

4 Low water pressure sensor connector

5 Low water pressure sensor

6 Low water pressure sensor retaining clip

7 Heating flow pipe retaining clip

8 Heating flow pipe

9 Heating flow pipe

10 Heating flow pipe retaining clip

11 Gas pipe

12 Flow sensor electrical plug

13 Flow sensor

14 Heating return pipe

15 Expansion vessel pipe

16 Plate-to-plate heat exchanger

17 Automatic air vent

18 Expansion vessel pipe clip

19 Automatic air vent retaining clip

20 Pump head retaining screws

21 Pump housing

22 Pump head connector

23 Plate-to-plate heat exchanger retaining screws

24 Safety Discharge Valve

25 bypass Valve

26 bypass Valve retaining nut

27 bypass Valve retaining nut

28 Impeller housing

29 Safety discharge valve plastic housing

30 Retaining clip

18.4.1

Pump (head only)

• Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

• Disconnect the electrical plug (22) from the main board.

• Remove the four cap head screws (20).

• Carefully remove the pump head (21) together with cable.

Do not strain cable.

• Reconnect wiring to new pump head and fit cover.

• Fit the new pump head by repeating the operations in reverse.

MAINTENANCE

- 40 -

Advertising