Maintenance – Glow-worm Easicom User Manual

Page 43

Advertising
background image

0020140413_01 - 09/12 - Glow-worm

18.4.2

Automatic air vent

• Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

• Remove the retaining clip (19). Remove the automatic air vent

(18).

• Fit the new automatic air vent and ‘O’ ring ensuring the vent

cap is left loose.

• Refill, vent and pressurise the boiler.

18.4.3

Low water pressure sensor

• Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

• Disconnect the electrical lead (4).

• Remove the retaining clip (6), remove the low water pressure

sensor (5).

• Fit the new low water pressure sensor.

• Refill vent and pressurise the boiler.

18.4.4

Safety discharge valve

• Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

• Remove the low water pressure sensor as described in the

previous section.

• Undo the safety discharge valve union and remove the pipe.

• Disconnect the Central Heating isolation valve.

• Remove the securing clips and withdraw the safety discharge

valve plastic housing (29).

• Remove the safety discharge valve.

• Fit new ‘O’ ring. Refill, vent and pressurise the boiler.

18.4.5

Flow sensor and impeller

• Remove the the electrical connection (12).

• Unclip the flow sensor (13).

• Unscrew the impeller housing (28) and remove the impeller.

18.4.6

bypass

• Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

• Remove the bypass valve retaining nut (26) to remove the

bypass from its housing (25).

• After replacing the bypass, refill, vent and pressurise the

boiler.

18.4.7

3 way valve motor and diverter valve

• Drain the boiler heating circuit as described in the appropriate

chapter "Draining".

• Disconnect the electrical plug (2).

• Remove the retaining clip (3).

• Remove the three way valve motor (1).

• Remove the diverter valve retaining nut.

• Remove the diverter valve.

• Fit new three way valve motor and diverter valve assembly.

• Refill, vent and pressurise the boiler.

18.4.8

Plate-to-plate heat exchanger

• Drain the boiler heating and domestic hot water circuits as

described in the appropriate chapter "Draining".

• Remove the two securing screws (23).

• Remove the plate-to-plate heat exchanger (17).

• When replacing the plate-to-plate heat exchanger, ensure that

the four rubber sealing washers are fitted into the hydroblock.

NOTE: The plate-to-plate heat exchanger only fits one way.

• Refill, vent and pressurise the boiler.