Multiple boiler chimney flue

Ø 60/100 mm (C43 type installation)

b

ATTENTION:

The flue connecting from the appliance to the flue

system must be supplied from the manufacturer of the

boiler.

b

ATTENTION:

C43 flue systems must not be a 'pressurised system' but

act under natural draught principles.

b

ATTENTION:

C43 type flue systems must have their own condensate

drain fitted and not allow condensate to mix into other

appliances.

L

B

A

1

2

3

4

5

Key

1 Pressure balancing system

2 Air-inlet pipe

3 Collector pipe

4 boiler

5 Inspection hatch

A final storey

B Ground floor

Type

Max length (L)

Ø 60/100

10 m

Each time an additional 90° bend is necessary (or 2 at 45°), the

length (L) must be reduced by 1 m.

Model

24

28

Exhaust mass rate (g/s)
At min thermal load (40°C/30°C)

3.6

3.74

At max thermal load (80°C/60°C)

8.3

10.8

Exhaust temperature (°C)
At min thermal load (40°C/30°C)

45

46

At max thermal load (80°C/60°C)

71.6

79

10 Electrical connections

e

DANGER:

Incorrect installation can cause electric shock or

appliance damage. The electrical connection of the

appliance must be made only by a qualified engineer.

The appliance must be connected directly to an accessible, fixed,

switched, electrical outlet.

The external wiring must be earthed, with correct polarity and in

accordance with current standards.

The manufacturer declines any responsibility for damages to

persons or others caused by the incorrect installation of the

appliance earthing. This includes failure to comply with current

standards.

Electrical components have been tested to meet the equivalent

requirements of the BEAB.

• Do not use cable greater than 10 mm in diameter for the

electrical connections.

All system components must be of an approved type.

• Do not interrupt the mains supply with a time switch or

programmer.

The boiler is suitable for installation in bathroom zones 2 and 3.

10.1 Access to main board

1

2

3

4

Key

1 24 V access cover

2 Terminal blocks for 24 V connection

3 Terminal blocks for 230 V connection

4 230 V access cover