10.3.2

230V permanent supply + 230V system controls

a

DANGER:

All cables connected to the appliance should be

permanently fixed to the wall.

i

IMPORTANT:

This appliance will not operate without a link or system

controls fitted.

24

V

4

5

6

7

2

1

3

Key

1 230V permanent supply

2 System controls

3 frost stat

4 Main board terminal block

FP = Frost stat 230V (switchable)

RT = Switch live (230V)

= Mains earth

N = Mains neutral

L = Mains live

5 Junction box

6 fuse

7 Double pole connector

• Connect the mains supply and system heating controls e.g.

room thermostat as described.

• When installing a 230v controller, the link fitted to the 24v

terminals (RT/24v) must be removed.

RT 24V

T° ext

BUS

10.4 External accessories

e

DANGER:

Under no circumstances must any mains voltage be

applied to any of the terminals on the 24v connection

plug.

230

V

X17

RT 24V

T° ext

BUS

BUS

24 V

3

2

1

Key

1 24V room thermostat connector

2 Ebus room thermostat connector or Ebus radio receiver

3 Outdoor sensor connector

• Fit external controls in accordance with the rules in force.

• When installing a non eBus controller, the link fitted to the 24V

terminals (RT/24V) must be removed.

10.5 Testing the electrical connections

Carry out preliminary electrical system checks as below:

- Resistance to earth (<1 Ohm)

- Short circuit test (L-N)

- Resistance to earth (L-E)

- Polarity check

INSTALLATION

- 19 -