Maintenance, 5 combustion block – Glow-worm Easicom User Manual

Page 44

Advertising
background image

0020140413_01 - 09/12 - Glow-worm

18.5 Combustion block

20

19

18

17

16

15

14

13

12

11

21

10

22

9

23

25

24

26

27

28

8

30

29

31

32

7

33

6

5

4

34

3

36

37

38

2

35

1

Legend

1 Igniter unit retaining bracket

2 Igniter unit

3 Igniter unit retaining screw

4 Igniter unit electrical connector

5 Electrode / igniter unit connection cable

6 Earth cable

7 Spark electrode cap

8 Spark electrode retaining screw

9 Spark electrode gasket

10 Spark electrode

11 Combustion burner door assembly

12 Combustion burner door assembly - nut

13 Combustion burner door assembly - seal

14 burner gasket

15 burner

16 Burner retaining screw

17 Heat exchanger retaining screw

18 Heat exchanger retaining bracket

19 Burner gate retaining screw

20 Thermal fuse connection

21 Heat exchanger

22 Heat exchanger retaining bracket

23 Heat exchanger retaining screw

24 Heating return pipe

25 Heating return pipe retaining clip

26 Return heating temperature sensor

27 Heating flow pipe

28 Flow heating temperature sensor

29 Heating flow pipe retaining clip

30 Gas valve retaining screw

31 Gas valve

32 Gas valve gasket

33 fan

34 fan electrical connection

35 fan/burner gasket

36 Gas pipe

37 Gas valve electrical connection

38 Fan retaining screw

MAINTENANCE

- 42 -

Advertising