Installation, 4 status of the appliance – Glow-worm Easicom User Manual

Page 27

Advertising
background image

0020140413_01 - 09/12 - Glow-worm

Code Parameter

Unit

Description

factory

setting

Modifiable

parameter

d.44 Digitalized ionisation voltage

V

Display the digitalized ionisation voltage. Multiply

the displayed value by 100.

-

no

d.68 Unsuccessfull ignitions at first attempt

-

Display the number of unsuccessfull ignitions at first

attempt.

-

no

d.69 Unsuccessfull ignitions at second attempt

-

Display the number of unsuccessfull ignitions at

second attempt.

-

no

d.80 Operating hours in heating mode

h

Display the number of operating hours in heating

mode. Multiply the displayed value by 100.

-

no

d.81 Operating hours in domestic hot water mode

h

Display the number of operating hours in domestic hot

water mode. Multiply the displayed value by 100.

-

no

d.82 Number of burner starts in heating mode

-

Display the number of burner starts in heating mode.

Multiply the displayed value by 100.

-

no

d.83 Number of burner starts in DHW mode

-

Display the number of burner starts in DHW mode.

Multiply the displayed value by 100.

-

no

d.93 Device Specific Number

-

Select the product code of the appliance:

24 -> 1

28 -> 2

yes

d.96 Factory reset

-

All parameters stored in EEPROM (main board +

appliance interface) are reset to factory settings if

this function is activated.

0 = deactivated

1 = activated

0

yes

12.4 Status of the appliance

• Press button for more than 3 seconds to learn the current

state of functioning of the appliance.

The screen displays "S" and the state of the appliance.

• Press and hold the

button for more than 3 seconds to

exit this menu.

Status

Heating Mode

S.00

No request for heating

S.01

Pre-run fan

S.02

Pre-run pump

S.03

Ignition

S.04

Burner lit

S.05

Post run pump/fan

S.06

Post run fan

S.07

Post run pump

S.08

Time delay anti short-cycles after heating

Status

Domestic hot water mode

S.10

Request for domestic hot water

S.11

Pre-run fan

S.13

Ignition

S.14

Burner lit

S.15

Post run pump/fan

S.16

Post run fan

S.17

Post run pump

Status

Specific messages

S.30

Default status, no request for heating or domestic water. If

an EBUS controller is connected to the boiler, check that a

wiring link is present on terminals 3 and 4 of the boiler's main

board.

S.31

"Hot water only" mode

S.32

Control cycle: the speed of the fan in the functioning phase is

outside tolerance.

S.34

"Frost protection" mode

S.41

Water pressure too high

S.53

Waiting cycle: temperature differential between heating flow

and return is too high. If ∆T > 30, forcing to Pmin.

S.54

Waiting cycle: lack of water in the installation/temperature

rise between heating flow and return is too high.

S.96

Test temperature sensor for heating return.

S.98

Test temperature sensors for heating flow and return, or the

appliance has a fault.

INSTALLATION

- 25 -

Advertising