9.2

Flue configuration description

9.2.1

Horizontal concentric flue Ø 60/100 mm

or Ø 80/125 mm (C13 type installation)

a

DANGER:

If necessary, you must install a terminal protection kit.

Ø 60/100 mm

L

63

1

Key

1 Gasket (fitted)

Ø 80/125 mm

L

1

Key

1 Gasket (fitted)

Type

Max length

Ø 60/100

6 m

Ø 80/125

10 m

Each time an additional 90° bend is necessary (or 2 at 45°), the

length (L) must be reduced by 1 m.

When using the Plume Management Kit, the maximum lengths

flue pipe A and B (60/100mm) are:

A

(m)

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5

b

(m)

5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5

• Refer to the Plume Management Kit installation manual.

9.2.2

Vertical concentric flue Ø 60/100 mm

or Ø 80/125 mm (C33 type installation)

L

Type

Max length (L)

Ø 60/100

6 m

Ø 80/125

10 m

Each time an additional 90° bend is necessary (or 2 at 45°), the

length (L) must be reduced by 1 m.