12.2 Installation settings

• Push in and hold the

button for more than 7 seconds to

access the configuration menu. The screen displays "0".

• Press the button 4 times. The screen displays "96". This is

the installer's password.

• Press

to validate. The screen displays a flashing and

alternating "d." and "00".

• Press or button to access the parameter to modify.

• Press

button to modify the value of the parameter and

select with the or keys.

• Press

button to confirm and save the changes.

• Press and hold the

button for more than 7 seconds to

exit.

Code Parameter

Unit

Description

factory setting Modifiable

parameter

d.00 Maximum heating power

kW

Choose a value: Easicom 24 > 8 to 18

and Easicom 28 > 8 to 24.

18 (Easicom 24)

24 (Easicom 28)

yes

d.01 Pump over-run time - heating

min

Choose a value between 2 and 60

5

yes

d.20 Maximum temperature setting for domestic hot water

°C

The recommended maximum temperature

setting for DHW is 60°C. Choose a value

suitable for your needs.

60

yes

d.34 Speed of fan

rpm

Fan speed is displayed between 0 and 99.

Multiply the display value by 100.

-

no

d.36 Domestic hot water flow

l/

min. Display domestic hot water flow.

-

no

d.40 Heating flow temperature

°C

Display the heating flow temperature.

-

no

d.41 Heating return temperature

°C

Display the heating return temperature.

-

no

d.43 Heating curve

K

See the instructions for the external sensor

connected to the appliance.

1.2

yes

d.47 Exterior temperature

°C

Display the temperature measured by the

external sensor.

-

no

d.67 Time remaining before the end of the anti-cycle in

heating mode.

min. Display the time remaining before the end of

the anti-cycle

-

no

d.71 Maximum temperature setting for heating outlet

°C

Select a value between 50°C and 80°C.

75

yes

d.90 Detection of eBUS controller

-

0 = Not detected

1 = Detected

-

no

12.3 After Sales Service settings

• Press and hold the

button for more than 7 seconds to

access the configuration menu. The screen displays "0".

• Press or button and enter the After Sales Service

password.

• Press

to validate. The screen displays a flashing and

alternating "d." and "00".

• Press or button to access the parameter to modify.

• Press

button to modify the value of the parameter and

select with the or keys.

• Press

button to confirm and save the changes.

• Press and hold the

button for more than 3 seconds to

exit the configuration menu.

Code Parameter

Unit

Description

factory

setting

Modifiable

parameter

d.08 Current state of the 230V room thermostat

-

230V room thermostat :

0 = open (no heating),

1 = closed (heating mode).

-

no

d.09 Flow temperature set point from external eBus control

°C

External eBus set value.

-

no

d.10 Heating pump status

-

0 = off

1 = on

-

no

d.16 Current state of the 24V room thermostat

°C

0 = open (no heating),

1 = closed (heating mode)

-

no

d.17 Flow or Return temperature control

°C

Temperature regulation on flow (radiator) or return

(under-floor heating) temperature sensor.

0

yes

d.22 DHW demand active (tapping)

-

0 = off

1 = on

-

no

d.23 Central heating mode

-

0 = CH not available (summer mode)

1 = CH available (winter mode)

-

no

d.33 Speed setpoint of fan

rpm

Fan speed is displayed between 0 and 99.

Multiply the displayed value by 100.

-

no

INSTALLATION

- 24 -

Advertising