VENTING INSTALLATION

INSTRUCTIONS

Continued

Your DESA direct-vent fireplace has been tested

for a minimum 3' rise with a maximum 11" wall

thickness. Any horizontal application longer than

12" must provide a minimum of 1 foot of vertical

rise for every 3 feet of horizontal run. The maximum

horizontal run is 20' with 8' vertical rise (see Instal-

lation for Horizontal Termination). The maximum

vertical run is 30' (see Installation for Vertical

Termination, page 114).
Installing Vent System in a Chase

A chase is a vertical box-like structure built to

enclose venting that runs along the outside of a

building.

NOTICE: Treatment of firestops

and construction of the chase

may vary from building type to

building type. These instruc-

tions are not substitutes for the

requirements of local building

codes. You must follow all local

building codes.

Note:

When installing in a chase, you should

insulate the chase as you would the outside walls

of your home. This is especially important in

cold climates. Minimum clearance between vent

pipes and combustible materials such as insula-

tion is 1".

After framing the chase (see Framing on page 6)

install the vent system by following the installa-

tion instructions.

INSTALLATION FOR HORIzONTAL
TERMINATION

1. Determine the route your horizontal venting

will take. Note: The location of the horizontal

vent termination on the exterior wall must

meet all local and national building codes and

must not be blocked or obstructed.

WARNING: Do not recess

vent terminal into a wall or sid-

ing. This is a fire hazard.

Snorkel terminations are available for termina-

tions requiring a vertical rise on the exterior of

the building (see Figures 12 and 13). Snorkel

kits are available for rigid pipe applications

only to provide a 14" rise and a 36" rise (see

page 17). Follow the same installation proce-

dures used for standard horizontal terminations.

If installing the snorkel termination to raise the

vent termination from below grade level such

as in a basement installation, you must provide

proper drainage to prevent water from entering

the snorkel termination (see Figure 13). Do not

back fill around the snorkel termination.

2. Rigid vent pipes and fittings have special

twist-lock connections. Assemble the desired

combination of pipe and elbows to the appli-

ance adaptor with pipe seams oriented towards

the wall or floor.

Figure 13 - Snorkel Termination with

Drainage Pipe

Figure 12 - Snorkel Termination

Snorkel

12" Minimum

90º

45º

Adequate
Drainage

Snorkel

12" Minimum

90º

45°

12"

Minimum

12"

Minimum

Advertising
This manual is related to the following products: