Installation – Desa DVF36TCR User Manual

Page 21

Advertising
background image

www.desatech.com

112108-01C

21

INSTALLATION

Continued

IMPORTANT:

The appliance and its individual

shutoff valve must be disconnected from the gas

supply piping system during any pressure testing

of that system at test pressures in excess of 1/2

psig. (3.5 kPa). The appliance must be isolated

from the gas supply piping system by closing its

individual equipment shutoff valve during any

pressure testing of the gas supply piping system

at test pressures equal to or less than 1/2 psig.

(3.5 kPa).

CAUTION: Do not kink flex-

ible gas line.

CAUTION: Compounds used

on threaded joints of gas piping

shall be resistant to the action

of Liquefied Petroleum (LP or

propane), and should be applied

lightly to ensure excess sealant

does not enter the gas line.

1. Install a sediment trap between the incoming

gas line and the gas control valve (see Figure

40). The sediment trap should extend down the

center of the pipe. Refer to your local codes.

2. Prepare incoming gas line and check with

local codes regarding the use of teflon tape.

Complete your gas line installation by con-

necting incoming gas line with flexible gas

line. Secure tightly with a wrench, but Do

NoT overTiGhTeN.

3" Min.

Side W

all

Of Appliance

Incoming 1/2" Gas
Line Permitted by
Local Codes

Figure 40 - Sediment Trap

Sediment
Trap (Not
Supplied)

WARNING: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is open, ap-

ply a soap and water solution

to all connections and joints. If

bubbles appear, leaks can be de-

tected and corrected. Do not use

an open flame for leak testing

and do not operate any appliance

if a leak is detected.

WARNING: Improper installa-

tion, adjustment, alteration, ser-

vice, or maintenance can cause

injury or property damage. Refer

to this manual. For assistance or

additional information, consult

a qualified installer, service

agency, or gas supplier.

GAS SUPPLY TESTING

Note:

This section is intended as a guide for

qualified service technicians installing gas to the

appliance.

CAUTION: Do not connect

appliance before pressure test-

ing gas piping. Damage to the

gas valve may result and an un-

safe condition may be caused.

The millivolt system with a manual HI/LO ap-

plies only to the DVF36TCR, DVF36TCRP,

DVF36TCL and DVF36TCLP models. The gas

control valve is accessible from the lower control

compartment. Two pressure taps are provided on

the gas control valve for a pressure gauge connec-

tion (see Figure 41, page 22).

The electronic system applies to the DVF36TCRE,

DVF36TCRPE, DVF36TCLE and DVF36TCLPE

models (see Figure 42, page 22).

Advertising
This manual is related to the following products: