Venting installation instructions, Continued – Desa DVF36TCR User Manual

Page 12

Advertising
background image

www.desatech.com

112108-01C

12

VENTING INSTALLATION

INSTRUCTIONS

Continued

Figure 16 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Wood Screw

Vent Cap

Figure 17 - Installing Siding Standoff

(Combustible Exterior Wall)

Cut Siding Away to
Fit Standoff

Wood
Screw

Screws

Standoff

Vent
Cap

Apply Mastic
to All Four Sides

Twist-lock Procedure:

The female ends of the

pipes and fittings have four locking lugs (in-

dentations). These lugs will slide straight into

matching slots on the male ends of adjacent

pipes and fittings. (All connections must be

sealed with high temperature silicone sealant

as specified in the second warning statement

on page 10.) Push the pipe sections together

and twist one section clockwise approximately

one-quarter turn until the sections are fully

locked. See Figure 14. Note: Horizontal runs

of vent must be supported every three feet. Use

wall straps for this purpose.

3. Attach vent pipe assembly to the fireplace using

twist lock connections. Set fireplace in front of

its permanent location to insure minimum clear-

ances. Mark the wall for a 10

3

/

4

" square hole (for

noncombustible material such as masonry block

or concrete, a 8

1

/

2

" diameter hole is acceptable).

See Figure 15. The center of the hole should

line up with the centerline of the rigid vent

pipe. Cut a 10

3

/

4

" x 10

3

/

4

" square hole through

combustible exterior wall (8

1

/

2

" diameter hole

if noncombustible). Frame as necessary.

4.

Noncombustible Exterior Wall:

Apply a bead

of non-hardening mastic around the outside

edge of the vent cap. Position the vent cap in the

center of the hole on the exterior wall with the

arrow on the vent cap pointing up. Attach the

vent cap with four wood screws provided (see

Figure 16). Note: Replace the wood screws

with appropriate fasteners for stucco, brick,

concrete, or other types of siding.

Combustible Exterior Wall:

For vinyl siding,

stucco, or wood exteriors, a siding standoff

must be installed between the vent cap and

exterior wall. The siding standoff prevents

excessive heat from damaging siding materials.

Siding materials must be cut to accommodate

standoff. Bolt the vent cap to the standoff.

Apply non-hardening mastic around outside

edge of the standoff. Position the standoff/cap

assembly in the center of the square hole and

attach to exterior wall with wood screws pro-

vided (see Figure 17). The siding standoff must

sit flush against the exterior fascia material.

Figure 14 - Vent Pipe Connections

Male
Slots

Female
Locking
Lugs

Figure 15 - Vent Opening Requirements

(Framing

Detail)

10

3

/

4

"

10

3

/

4

" Inside Framing

10

3

/

4

"

8

1

/

2

"

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall