Venting installation instructions – Desa DVF36TCR User Manual

Page 16

Advertising
background image

www.desatech.com

112108-01C

16

Venting with Two

90° Elbows

Vertical Horizontal
(V

1

)

(H)

5' min.

6' max.

6' min. 12' max.
' min. 18' max.
8' min. 20' max.

Figure 28 - Vertical Rigid Venting

Configuration Using Two 90° Elbows

Venting with One 90° Elbow

Vertical (V) Horizontal (H)

5' min.

2' max.

6' min.

4' max.

' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Figure 27 - Vertical Rigid Venting

Configuration Using One 90° Elbow

Venting with Two 90° Elbows

Vertical (V) Horizontal (H

1

) +

Horizontal (H

2

)

5' min.

2' max.

6' min.

4' max.

' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Figure 26 - Vertical Rigid Venting

Configuration Using Two 90° Elbows

with Two Horizontal Runs

5. Complete the cathedral ceiling installation

by following the same procedures outlined in

steps 2 through 7 for Flat Ceiling Installation,

page 14.

Vertical Termination Configurations

Figures 26 through 29 show four different configu-

rations for vertical termination. These minimum

vertical rises are based on horizontal runs with a

minimum of 1/4" upwards pitch per foot and do

not reflect constraints on a vertical system with

45° or greater offset.

Any offset pitch of 45° or less must be considered

horizontal and sized within the maximum allow-

able lengths listed in the following examples. All

connections must be sealed with high temperature

silicone sealant as specified in the second warning

statement on page 10.

VENTING INSTALLATION

INSTRUCTIONS

Continued

45° Starter
Elbow

Note: Install
restrictor into inner
collar of fireplace
as shown.

45° Starter
Elbow

Note: Install
restrictor into
inner collar of
fireplace as
shown.

45° Starter
Elbow

Note: Install
restrictor into inner
collar of fireplace
as shown.

Advertising