Venting installation instructions – Desa DVF36TCR User Manual

Page 13

Advertising
background image

www.desatech.com

112108-01C

13

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Firestop

Horizontal
Vent Pipe

Figure 18 - Connecting Vent Cap with

Horizontal Vent Pipe

Screw

VENTING INSTALLATION

INSTRUCTIONS

Continued

5.

Combustible Exterior Wall Only:

Slide

interior wall firestop over vent pipe before

connecting horizontal run to vent cap (see

Figure 18).

Horizontal Termination Configurations

Figures 19 and 20 show different configurations for

venting with horizontal termination. Each figure

includes a chart with vertical minimum/maximum

and horizontal maximum dimensions which must

be met. All connections must be sealed with

high temperature silicone sealant as specified in

the second warning statement on page 11. All

horizontal terminations require 1/4" rise per 12"

of horizontal run. You must add 1/4" of vertical

height (V) in the following tables for each foot of

horizontal run (H).

Figure 19 - Horizontal Termination

Configuration for Rigid Venting Using

One 90° Elbow

Horizontal Venting

Vertical (V)

Horizontal (H)

49.5" min.*

1" max.*

60" min.

" max.

2" min.

101" max.

84" min.

125" max.

132" min.

149" max.

(45° elbow, 1' vertical pipe, 90° elbow)

45° Starter
Elbow

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

Horizontal (H2)

5' min.

4' max.

6' min.

8' max.

' min.

10' max.

8' min.

15' max.

20' max.

20' max.

Figure 20 - Horizontal Termination

Configuration for Rigid Venting Using

Two 90° Elbows with Termination at 90°

with Fireplace

45° Starter
Elbow

Advertising