Installation, Continued, Electrical hookup for optional blower accessory – Desa DVF36TCR User Manual

Page 19

Advertising
background image

www.desatech.com

112108-01C

19

INSTALLATION

Continued

Figure 33 - Removing Louver

Glass

Locating
Holes

Spring Latch

Recommended
Blower Speed
Control
Location

ELECTRICAL HOOKUP FOR
OPTIONAL BLOWER ACCESSORY

Before blower accessory can be operated, the ap-

pliance outlet box must be properly connected to

a standard 120 VAC power source. This must be

done when the appliance is originally installed.

Refer to Wiring Diagrams on page 31.

An outlet box with two receptacles has been sup-

plied for your convenience and is located on the

lower right side of the appliance (see Figure 34).

The variable speed controller is mounted on a

magnetic base and may be positioned anywhere

within an accessible distance behind the louvered

opening (see Figure 33).

You may test the blower for operation by turning

the control knob clockwise just until it clicks on

which is the full on position. Adjust the fan speed

to the lowest setting (this should be no more than

1/4 of a turn clockwise).

Figure 34 - Connecting Blower

Accessory to Power Supply

For Optional
Fan Kit

From Blower
Assembly

OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL INSTALLATION

Note:

If using an optional wireless hand-held

remote control, the wall switch is no longer

operational.

NOTICE: Only use alkaline bat-

teries (not included).

Installing HRC100 Model Remote Control
(Millivolt Models Only)
1. Remove lower louver access panel in fire-

place (see step 1 of Wall Switch Installation,

page 18).

2. Disconnect wall switch wires from termi-

nals marked TH and TPTH (see Figure 32,

page 18).

3. Slide 9-volt battery into clip on back of remote

receiver and connect battery terminals to bat-

tery. Mount receiver onto bracket with clips

provided (see Figure 35).

4. Connect white wire to control valve terminal

TH and red wire to TPTH. Move remote select

switch to REMOTE position.

5. Replace louvered access panel by following

reverse of step 1 under Wall Switch Installa-

tion, page 18.

6. Remove battery cover on back of hand-held

remote (see Figure 36, page 20). Remove and

discard sensor tag.

7. Attach terminal wires to 9-volt battery. Place

battery into housing.

8. Replace battery cover onto hand-held remote.
9. Set selector switch on receiver to OFF posi-

tion if you will be away from the unit for an

extended period of time.

FRONT

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Figure 35 - Installing Remote Receiver

(HRC100)

Gas
Valve

To Thermopile

Receiver Clip

Terminal
Wires

Plastic Mounting Clips

9-Volt Battery

White

Red

CAUTION: Due to high tem-

peratures, make sure wires are

not touching upper firebox.

Advertising