Installation, Continued, Gas line hook-up – Desa DVF36TCR User Manual

Page 20

Advertising
background image

www.desatech.com

112108-01C

20

INSTALLATION

Continued

Installing SKYTECH/WRC Model Remote
Control (Electronic Models Only)
1. Remove lower louver access panel in fire-

place (see step 1 of Wall Switch Installation,

page 18).

2. If a wall switch was installed, it must be

removed from ignition control circuit for

remote to work properly. Remove wire nuts

from switch connection at ignition control

module. Using wire nut, connect transformer

(blue) wire to remaining wire connected to

control terminal marked P.SW (see Figure

36, page 18).

3. The receiver does not require a battery. To

install, plug extension cord into one of the

outlet receptacles on the outlet box. Plug re-

ceiver unit into extension cord and the ignition

module into receiver unit (see Figure 37).

4. Replace louvered access panel by following

reverse steps on page 18.

5. Activate handset battery by removing insulat-

ing tab on back (see Figure 38).

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Gas
Valve

To Thermopile

Extension

Cord

Outlet Box

White

Red

Figure 37 - Installing Remote Receiver

(SKYTECH Model)

Optional Fan
Kit Plug

Receiver

Pull to Remove
Insulation Tab

Battery
Cover

12 Volt
Battery

Figure 38 - Installing Battery in Hand-

Held Remote Control Unit (SKYTECH)

GAS LINE HOOK-UP

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

WARNING: Gas line hookup

should be done by your gas

supplier or a qualified service

person.

An equipment shutoff valve has been included in

the appliance’s gas supply system. You may con-

sider installing an extra gas shutoff valve outside

the appliance’s enclosure (check with local codes)

where it can be accessed more conveniently with a

key through a wall as shown in Figure 39.

Route a 1/2" NPT black iron gas line towards the

appliance coming in from the left. It is recom-

mended to route the pipe between the stand of

the firebox and the surround of the fireplace (see

Figure 40, page 21).

Figure 39 - Typical Exterior Wall Gas

Shutoff Installation

Key

Extension

Shutoff Valve

9-Volt Battery

Battery
Housing

Figure 36 - Installing Battery in Hand-

Held Remote Control Unit (HRC100)

Battery
Cover

Terminal
Wires

Remote Control Unit

Sensor
Tag