CLEARANCES

Minimum clearances to combustibles for the fire-

place are as follows:

Back and Sides of Surround*

0"

Vent Surface (Side and Bottom)

1"

Top Vent Surface (Horizontal Run)

2"

Ceiling to Opening

36"

Floor

0"

Wall to Front of Glass

36"

Perpendicular Wall to Opening of Unit

2"

Top Spacer

0"

* For back and sides of fireplace, do not pack

with insulation or other materials. Zero inch

clearance to combustible materials are for fram-

ing purpose only.

NOTICE: This fireplace is in-

tended for use as supplemental

heat. Use this fireplace along

with your primary heating sys-

tem. Do not install this fireplace

as your primary heat source.

If you have a central heating

system, you may run system’s

circulating blower while using

fireplace. This will help circulate

the heat throughout the house.

In the event of a power outage,

you can use this fireplace as a

heat source.

MANTEL CLEARANCES

Woodwork, such as wood trims, mantels and other

combustible materials should not be placed within

7" of the opening of this fireplace (see Figure 5).

Combustible material above projecting more than

1

1

/

2

" from the appliance’s front face must not be

placed less than 15" from the opening of the appli-

ance (ref. NFPA Standard 211 Sec. 7-3.3.3).

PRE-INSTALLATION

PREPARATION

Continued

0"

36"

2"

Wall In Front Of Glass

36" Min.

Perpendicular

Wall 2" Min.

From Opening

Right Side

Surround

(0" Min.)

Left Side

Surround

(0" Min.)

TOP VIEW

Figure 3 - Minimum Clearances

Figure 4 - Minimum Clearances

CEILING

WALL

36" Min.

36" Min.

0" Floor

FRAMING

Once the final location has been determined, ob-

serving clearances for the vent termination, you

may construct framing using dimensions shown

in Figures 6 to 10 on page 7 depending on your

particular installation

If the appliance is to be installed directly on carpeting,

tile (other than ceramic), or any combustible mate-

rial other than wood flooring, the appliance must be

installed upon a metal or wood panel extending the

full width and depth of the appliance. There are three

holes on each side of the bottom of the unit where

screws can be used to secure the unit to the floor.

Figure 5 - Mantel Clearances

21" Min.

15" Min.

12" Min.

4"

Min.

7" Min.

1

1

/

2

" Max.

UNIT

Spacer

2 x 4

Combustible
Material May
Be Used

Drywall (Gypsum
Board, Sheetrock, Etc.)

Safe Zone for
Projection of
Combustible
Material

Advertising