Installation, Venting installation instructions, Continued – Desa DVF36TCR User Manual

Page 18: Wall switch installation

Advertising
background image

www.desatech.com

112108-01C

18

Number Description
E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

FSE58-45 45° Starter Elbow (Dura Vent to

FMI Pipe)

FP-58

Firestop Plate

WF-58

Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch,

Galvanized

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch,

Galvanized

S-58

Vinyl Siding Standoff,

Galvanized

VT-58

Vertical Round Termination,

Galvanized

HHT-58

High WInd Round Horizontal

Termination Kit, Galvanized

HTS-58

Square Horizontal Termination,

Galvanized

HHTK-58 High Wind Round Horizontal

Termination Kit

(Includes Round Termination,

Wall Firestop, 45° Elbow)

ST-58-14 14" Snorkel Termination,

Galvanized

ST-58-36 36" Snorkel Termination,

Galvanized

SF-58

Stucco Flashing -

For use with HTS-58

VR-58

Vertical Restrictor, Galvanized

WS-58

Wall Strap

SC-58

Storm Collar, Galvanized

CS-58

Cathedral Ceiling Support

VENTING INSTALLATION

INSTRUCTIONS

Continued

INSTALLATION

WALL SWITCH INSTALLATION

The electronic version uses a 24 VAC current sup-

plied from a transformer mounted on the ignition

module and is prewired for easy connection to a

wall switch (see Figure 31). The millivolt version

uses a self generated millivolt current that allows

you to activate the gas control valve directly with-

out the use of normal household electricity (see

Figure 32). Both versions are supplied with a wall

switch kit for ready connection and mounting.

WARNING: Do not wire re-

mote wall switch to main power

supply (Standard 120V house-

hold current).

V1

SW

SI

TS

IND

V2

L1

D

N

G

P.

Figure 31 - Wall Switch Wiring Diagram,

Electronic Units

Route 24V (Supplied)
Through Electrical
Conduit Bushing

Electrode

Transformer

Plug 120V AC
To Receptacle

18 AWG
Red Wire

Wall Switch

(Supplied)

Make Connections
with Wirenuts
(Supplied)

Ignition
Control
Module

(Back
View)

V1

SW

SI

TS

IND

V2

L1

D

N

G

P.

Figure 32 - Wall Switch Wiring Diagram,

Millivolt Units

Note:

If any of the original wire supplied must be

replaced, use type 18 AWG-105° C (25 feet length

maximum) or equivalent.

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

Wall Switch
(Supplied)

Route Millivolt Wires
(Supplied) Through Gas
Line Conduit Sleeve

To

Thermopile

(Back
View)

OFF

P

IL

O

T

ON

LO

HI

PI

LOT

E

A

16AI

7

TPTH

TP

TH

1. To remove the louvers, simultaneously pull

both top end spring latches towards the center

of the appliance until they are disengaged

from locating holes. Repeat for bottom spring

latches and pull louvers outward. Reverse the

procedure to install louvers back onto the ap-

pliance (see Figure 33, page 19).

2. Connect the 18 gauge wires from wall switch

to the gas control valve terminals marked TH

and TPTH or to the ignition module using the

pigtails and wire nut connectors supplied with

the appliance.