Troubleshooting – Desa DVF36TCR User Manual

Page 29

Advertising
background image

www.desatech.com

112108-01C

29

TROUbLESHOOTING

WARNING: Turn off heater, disconnect power if applicable and

let cool before servicing. Only a qualified service person should

service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean

pilot. This can damage pilot unit.

Note:

The two most common causes of malfunctioning gas appliances are loose wiring connections

and construction debris clogging pilot and/or control valve filter.
Note:

Before troubleshooting the system make sure gas shut off valve is open.

MILLIVOLT SYSTEM

REMEDY

1. Check gas supply

2. Hold control valve in the

PILOT position for 2 to 3

minutes to purge air. If you

smell gas stop and wait a few

minutes before trying to light

fireplace

3. Remove debris and dirt, in-

spect and clean any other

possible obstructions

4. Contact your gas supplier

5. Refer to section on pilot

lighting

6. Have a qualified technician

replace pilot line

7. Replace control valve

8. Tighten thermocouple or re-

place

1. Check wiring connection. Refer

to Wiring Diagrams, page 31

1. Check electrical connections

2. Re-check problem "Pilot Will

Not Stay Lit"

1. Clean and adjust pilot flame for

maximum flame impingement

on thermopile

1. Replace thermopile

POSSIBLE CAUSE

1. No gas supply, or shutoff valve

is OFF

2. Air in gas line

3. Construction debris clogging

pilot orifice

4. Low gas pressure

5. Control valve knob is not on

the PILOT position

6. Kinked pilot line

7. Bad valve

8. Bad thermocouple or loose

connection

1. Loose wiring on thermopile to

regulator valve. No millivolt

current being sent to regulator

1. Wall switch wires defective

2. Thermopile generator or sensor

not generating sufficient voltage

1. Pilot flame may be too low,

causing safety pilot to “drop

out”

1. Millivolt output on thermopile

too high

PROBLEM

Pilot will not light

Pilot will not stay lit

No gas to burner, although wall

switch and valve are set to the

ON position

Frequent pilot outage

Pilot goes out when wall switch

is on