Wiring diagrams, Troubleshooting, Continued remedy – Desa DVF36TCR User Manual

Page 31: Possible cause, Problem

Advertising
background image

www.desatech.com

112108-01C

31

TROUbLESHOOTING

Continued

REMEDY

1. Check ignition wire connec-

tion (see Wiring Diagrams)

2. Check ground wire connection

(see Wiring Diagrams)

3. Clean and adjust main burner;

check gas supply and inlet

pressure; replace ignition as-

sembly if necessary

1. Check electrical connections

and replace wall switch

1. Clean and adjust main burner

2. Adjust ignitor location for

maximum flame impingement

on sensor

3. Have vent inspected for block-

age or damage

POSSIBLE CAUSE

1. Loose wiring on ignition

module

2. Poor ground to ignition

module

3. Main burner flame too low

to sense

1. Wall switch wires defec-

tive

1. Burner flame is too low

2. Igniter is misaligned causing

safety burner to "drop out"

3. Vent may be blocked or

restricted

PROBLEM

Burner will not stay lit

No gas to main burner when wall

switch and valve are set to ON

position

Frequent main burner outage

WIRING DIAGRAMS

GND

J. BOX RECEPTACLE

GRN

BLK

WHT

BREAKER)

GRN

(NOT SUPPLIED)

INCOMING
120V AC

(FUSE BOX

FIELD WIRE

WHT

BLK

OR

CONNECTORS

Variable
Speed
Control

Blower

Electrical Rating:
120v, 60Hz, 0.7A

TRANSFORMER

STEP DOWN

120V AC

24V AC

OFF

WALL SWITCH

(SUPPLIED)

ON

IGNITER

ASSEMBLY

D V2

G
N

L1 IND

IGNITION CONTROL

MODULE

TS S1

SW V1

P.

120 VAC

GND

J. BOX RECEPTACLE

OPTIONAL

CONTROL

REMOTE

GRN

BLK

WHT

BREAKER)

GRN

(NOT SUPPLIED)

INCOMING
120V AC

(FUSE BOX

FIELD WIRE

WHT

BLK

OR

CONNECTORS

E

A

I

H

L

O

I

P

T

O

L

CONNECT

VALVE TO

CONTROL

DO NOT

GAS VALVE

Figure 60 - Electronic Wiring Diagram

Figure 61 - Optional Blower Wiring Diagram