8.12 - Selection Object

Class ID 2E

hex

Instance ID 1 (setpoint)

Attribute 0E determines

the selection between

pressure control or valve

control (1 for pressure

control, 2 for position

control), default is 1

after reset.

A change on attribute 0E

only becomes effective

once a new setpoint is

sent (attribute 0F)

When in pressure

control (destination used =1)

writing a new setpoint is

immediately tasking the

controller to regulate to the

designated pressure

When in position control

(destination used=2) writing a

new setpoint will directly

affect the valve position

TAbLE 8.12.1 – SELECTION ObJECT ATTRIbUTES; INSTANCE 1

attrIBute Id

hex

ServIce Id

HEx

name

Format

value

1

0E (get)

State

USINT

0 = Non-existent
1 = Idle
2 = Running

2

0E (get)

Max destinations

UINT

02

3

0E (get)

Number of destinations

UINT

02

4

0E (get)

Destination List

Array of

STRUCT of

{Path length

(USINT)

Destination

path (EPATH)}

06 20 33 24 01 30 06 - S-Single Stage

Controller, Instance 1, setpoint
06 20 33 24 02 30 06 - S-Single Stage

Controller, Instance 2, setpoint

5

0E (get)

Max sources

UINT

00

6

0E (get)

Number of sources

UINT

00

8

0E (get)

Source used

UINT

00

0A

0E (get)

Algorithm type

USINT

04 = Programmable data flow

0D

0E (get)

Object source list

Array of

STRUCT of

{Path length

(USINT)

Destination

path (EPATH)}

00

0E

0E (get) 10 (set)

Destination used

UINT

Range = 0-2

0F

0E (get) 10 (set)

Input data value

UINT

Data type determined by destination used

T

AbLE 8.12.2 – SELECTION ObJECT ATTRIbUTES; INSTANCE 2

attrIBute Id

hex

ServIce Id

HEx

name

Format

value

1

0E (get)

State

USINT

0 = Non existent
1= Idle
2 = Running

2

0E (get)

Max destinations

UINT

01

3

0E (get)

Number of destinations

UINT

01

4

0E (get)

Destination list

Array of

STRUCT of

{Path length

(USINT)

Destination

path (EPATH)}

06 20 32 24 01 30 06 - S-Analog
Actuator Object, Instance 1, Value

5

0E (get)

Max Sources

UINT

02

6

0E (get)

Number of sources

UINT

02

8

0E (get)

Source used

UINT

00

0A

0E (get)

Algorithm type

USINT

04 = Programmable data flow

0D

0E (get)

Object source list

Array of

STRUCT of

{Path length

(USINT)

Destination

path (EPATH)}

06 20 33 24 01 30 09 - S-Single Stage
Controller Instance 1, Control Variable
06 20 33 24 02 30 09 - S-Single Stage
Controller, Instance 2, Control Variable

0E

0E (get) 10 (set)

Destination used

UINT

01

0F

0E (get) 10 (set)

Input data value

UINT

Data type determined by
S-Analog Actuator data type