Ntellisys, Daptive, Ressure – Nor-Cal IQ+ Adaptive Pressure Controller User Manual

Page 5: Ontrollers, 0 - device specification

Advertising
background image



Call toll free

800-84-4166

or 530-842-4457

FAX 530-842-9130

I

ntellIsys

A

dAptIve

p

ressure

C

ontrollers

IQ+ OP-LIT 9/08

2.0 - Device Specification

The following tables summarize specifications essential to the installation and hook-up of the IQ+ product. Please note that the information herein is limited to
the IQ+ controller. For valve installation instructions and guidelines, please refer to the appropriate Valve Operating Manual.

TAbLE 2.3 –IQ+ CONTROLLER RS-232 SERIAL I/O

Feature

SPecIFIcatIon

Communications Settings

Factory configured at 9600 baud, 1 stop bit,

no parity, 8-bit character

Connections

Rxd Data, Txd data and Common.

No handshake connections.

Communications Protocol

See Section 6.0 in this manual

End of line delimiter

Carriage return (ASCII 0x0D) or Line Feed (ASCII

0x0A) or carriage return then line feed in that order

TAbLE 2.4 – IQ+ CONTROLLER PERFORmANCE

Feature

ButterFly

valveS

Gate & Pendulum valveS

Valve speed

(open to closed)

125 to 250 msec,

depending on valve size

2 to 5 sec, depending on valve size

Control range

0.5% to 100% of

gauge

0.5% to 100% of gauge

Accuracy

0.25% of reading (5mV

min)

0.25% of reading (5mV min)

Repeatability

0.12% of reading

0.12% of reading

TAbLE 2.5 – IQ+ CONTROLLER RELIAbILITy

Feature

ButterFly valveS

Pendulum valve

Electronics MTBF

>10,000 hours

>10,000 hours

Warranty

1 year

1 year

TAbLE 2.1 – IQ+ CONTROLLER GENERAL EQUIPmENT SPECIFICATIONS

Feature

SPecIFIcatIon

Dimensions

Please refer to the diagram specific to sections 3.1 to 3.5

Weight, in lbs (kg)

1.1 lb (0.5 kg)

Rated Input Voltage

24 VDC ±10%

Rated Current

5.0 A @ 24 VDC max, 1.5 A @ 24 VDC average

Rated Input

Protection

29 Volts max, reverse and current limited

Gauge Power Supply

(Optional)

± 15 VDC @ 1400 mA

Protection Class

I

Degree of Protection

(IP)

X0

Laser Class

1 (LED’s)

Certifications/EU

Directives

CE Standard for Process Equipment including EMC Directive

89/336/EC for D/C powered models..

Maximum Altitude

6562 ft (2000 m)

Allowable Ambient

Operating

Temperature

32ºF to 113ºF (0ºC to 45ºC)

Allowable Ambient

Humidity

0 to 95% non-condensing

Installation Clearance

3” (75 mm) on all perforated sides. A minimum of 3½”

(90 mm) is needed to allow for connectors. If access and

line of sight is required for LED’s and switches a minimum

of 6” (150mm) is required on those sides.

TAbLE 2.2 – IQ+ CONTROLLER ANALOG TTL I/O

Feature

SPecIFIcatIon

Analog (Gauge) Input

0 to 10V differential

Analog Output

0 to 10V unipolar @ 35 mA, short circuit protected

TTL Input

Diode protected at –0.4 VDC, compatible with open

collector relay closure or standard logic signals, 25V max.

Maximum low input voltage is 0.6V and minimum sink

current is 1 mA. Minimum high input voltage is 2.5V, or

open.

TTL Output

Open collector, optically isolated, 25V @ 10 mA max

Advertising