Controller assignments – Rocktron Replifex User Manual

Page 44

Advertising
background image

41

Controller Assignments

The Controller Assignment function allows for specific Replifex

™

adjustable parameters to be mapped

(or assigned)* to a MIDI controller for real-time control by an expression pedal.

The Controller Assignment option also lets you store an upper and lower parameter value limit which

the controller cannot exceed. For example, when using an expression pedal with a Rocktron All Access

™

or MIDI Mate

™

footswitch to send continuous control changes to control the "PITCH" parameter, an upper

limit of +300 can be set and a lower limit of -200 can be set - even though the actual parameter range is

from +1200 to -2400. When the expression pedal is at its heel position in this example, the "PITCH"

parameter will be at -200, while at its toe position it will be at +300. Up to ten controllers can be assigned

for each individual preset.

Operating the Replifex

Step 1

Step 2

To access the Controller Assign function, turn the FUNCTION SELECT control clockwise to
"CONTROLLER ASSIG".

This parameter (CTR A only) also gives you the option of selecting "ADJ". When "ADJ" is
selected, the parameter assigned to the first controller (PA-A) can be instantly accessed by
turning the PARAMETER ADJUST control when the preset title is displayed. This allows you
to access a parameter that you adjust frequently without paging through function headings
and parameters.

Turn the PARAMETER SELECT control for the first parameter of the Controller Assign
function. This parameter allows you to select a controller number for the "CTR A" (Controller
A) parameter to respond to.

CONTROLLER ASSIG

CTR A

XXX

4,7,10,13

2,5,8,11

1

3,6,9,12

Advertising