CONDITIONS

Input Level pot minimum

Output Level pot maximum

Input Level pot minimum
Input Level pot maximum

Peak Signal/A Weighted Noise Floor,
Direct Level = +6dB, Direct Post HUSH,
Effects Level = -

1kHz, -5dB input level
22Hz to 22kHz bandwidth
Direct Level = +6dB, Direct Post HUSH,
Effects Level = -

TECHNICAL DATA

Technical Data

MEASUREMENT

Maximum Input:

+ 2 0 d B u

Maximum Output:

+ 2 0 d B u

Nominal Input Range:

+4dBu to

(16dB Headroom)

-21dBu

Input Impedance:

470K ohms

Output Impedance:

120 ohms

Dynamic Range:

104dB (HUSH IN)
94dB (HUSH OUT)

T H D + N

.009%

Dry Frequency Response

(10Hz to 100kHz) +.25, -2dB
(10Hz to 30kHz) ±.25dB

Wet Frequency Response

(20Hz - 14.5kHz) +5, -3dB