Nexen TC920V 964356 User Manual

Page 35

Advertising
background image

32

FORM NO. L21268-C-1013

PARAMETER

RANGE/TYPE

Input Power

100 to 240VAC, 50/60Hz

Power Consumption

300VA

Product Mass

13.2 lbs [6 Kg]

Ambient Temperature

32 to 120°F [0 to +50°C]

Rated Tension

0-2000 lbF (10 to 10000N)

Digital

Input

Signals

Auto Trigger

12 VDC, 12 mA

Memory Reset

Acceleration/Deceleration Reset

Splicing

Control Output ON/OFF

Emergency Stop or Automatic/Manual Selection,

Acceleration

Measurement Diameter Reset

Measurement Diameter Hold

Analog

Input

Signals

External Manual Output

0-5 VDC

External Tension Setpoint

Analog Diameter Measurement

0-10 VDC

New Shaft Diameter

External Shaft Level

External Taper Ratio

Digital

Output

Contact

Zero Tension Alarm

40 VDC, 0.2A

200 VAC, 0.2A

Over Tension Alarm

Minimum Diameter Alarm

Analog

Output

Signals

Tension Measurement Output

0-10 VDC, 1mA max

0 to 1mA

Control Output

0-10 VDC, 1 mA max

4-20 mA, 470

Ω max

0-24 VDC, 4A max (Magnetic Particle)

Digital

Encoder

Excitation Voltage

12V DC ±10%

Current Consumption

50mA or less

Logic Level

Logic High

≥ 10V DC

Logic Low

≤ 1V DC

Maximum Switching Frequency

25 kHz max

Proximity

Sensor

Excitation Voltage

12V DC ±10%

Current Consumption

50mA or less

Logic Level

Logic High

≥ 10V DC

Logic Low

≤ 1V DC

Response Frequency

Min 500Hz

10. SPECIFICATIONS