Wiring integral holding brakes, 36 sv7 hardware manual – Applied Motion SV7-C-CE User Manual

Page 36

Advertising
background image

36

SV7 Hardware Manual

920-0012F

12/18/2014

Wiring Integral Holding Brakes

The integral holding brakes of AMP servo motors require between 200 and 400 mA at 24 VDC to

operate properly. To wire and operate a holding brake from the Y1/Brake output of an Applied

Motion servo drive requires the following items:

• A 24 VDC power supply with minimum output of 450 mA

• A 24 VDC relay*

• A clamp diode such as 1N4935*

• An AMP servo motor with integral holding brake, designated by a “5” in the 7th position of the

motor part number. Example: M0400-151-4-000

• A “BK” type motor power cable or separate brake cable. Example: BLUMTR-BK-FA-10

* Relays with an integral clamp diode, like IDEC part number RU2S-D-D24, greatly simplify the wir-

ing effort by including the relay and a clamp diode in one unit.

Following the diagram below, connect the power supply, relay, and diode to the brake leads of the

servo motor, as well as the Y1/Brake output connections of the servo drive.

Y COMMON (pin 17)

Y1 / Brake (pin 14)

24 VDC

power

supply

BLUE br

ak

e lead

YELLO

W br

ak

e lead

24 VDC relay

clamp diode

Advertising