Setting Drive Current Limits

The SV7 allows the user to set both the Motor Continuous and Peak current limits. Current settings

are an RMS value. Using the

QuickTuner™ the current settings can be uploaded and downloaded.

Setting the current limits requires the user to know the limitations of the motor. In most cases refer-

ring to the motor manufacturers specification will give the proper information. For AMP motors,

motor settings are available in parameter files that are located on the PC where QuickTuner™ was

installed.

What is “Peak Current Limit”?

The SV7 uses this current value to establish the maximum possible RMS current that will be driven

to the motor. The peak current time is set to one second. That is, if the drive attempts to run at peak

current for more then one second it will fold back the current to the continuous current setting.

The peak current time is actually calculated on a curve using an I²/T method. For current values that

are less than the peak but greater than the continuous, the current foldback time is calculated from

the peak and continuous settings. As shown in the diagram below, current values below the peak

value can be used for longer periods of time.