System components overview – d&b J-Series User Manual

Page 7

Advertising
background image

2.1.1. System components overview

Pos.

Component

Description

[1]

Z5300 J Flying frame

The Z5300 J Flying frame is designed to support arrays consisting of
the following J-Series loudspeakers:

Code

Type

Weight incl. rigging comp.

Z0650

J8

60 kg (132 lb)

Z0651

J12

60 kg (132 lb)

Z0660

J-SUB

106 kg (234 lb)

The weight of the J Flying frame including all rigging components is
65 kg (143 lb)

[1.1]

[P]

J Load adapter

Park position J Load adapter

The J Flying frame is supplied with two J Load adapters to allow single
or dual hoist set up. Each J Load adapter is supplied with a pair of
Locking pins 12 mm and a 3.25 t shackle. During transport the Load
adapters should be stored at their park position [P]. (please refer to
section 3.5 Suspension of the Z5300 J Flying frame on page 13)

[1.2]

Safety point(s)

The J Flying frame is equipped with a total of four safety points to
attach a secondary safety using the Z5303 J Safety chain and 3.25 t
Shackles. (please refer to section 3.6 Secondary safety on page 15)

[1.3]

Mounting plate

The J Flying frame is equipped with an additional mounting plate to
accept industry standard inclinometers such as Rieker Instrument
Company Inc. or SSE ProSight Inclinometer System.

[1.4]

Cable pick

An O-Ring can be slid out by releasing the respective Locking pin for
attaching a cable pick.

[1.5]

Locking Pins 11 mm

Two additional Locking pins 11 mm are supplied with the Flying frame
and are located beside the cable pick. They are used to connect J-
Series cabinets on top of the Flying Frame for the following set ups:

Mixed J-Series array with J-SUB cabinets at the top of the column.
(Section. 4.2 Variant 2: J-SUB and J8/J12 Arrays from page 22)

J-Series ground stack with the J Flying frame as ground support.
(Section. 4.4 Variant 4: J-Series ground stacks from page 26)

[1.6]

Splay link (Frame)

In conjunction with the Front links of the J-Series loudspeaker cabinets
the Splay link of the frame is used to attach the first cabinet to the
frame. By factory default the Splay link of the frame is fixed in J8/J12
position. To accept J-SUB cabinets the Splay link can be moved to J-
SUB position. (please refer to section ofon page )
During transport the Splay link should be fold back to its park position
and secured by the respective Locking pin.

[1.7]

Front link (Frame)

Two additional Front links together with a pair of Locking pins 10 mm
each are supplied with the J Flying frame. They are used to connect J-
Series cabinets on top of the Flying Frame for the following set ups:

Mixed J-Series array with J-SUB cabinets at the top of the column.
(Section. 4.2 Variant 2: J-SUB and J8/J12 Arrays from page 22)

J-Series ground stack with the J Flying frame as ground support.
(Section. 4.4 Variant 4: J-Series ground stacks from page 26)

J-Series Rigging manual

(1.3 EN)

Page 7 of 34

Advertising